Key takeaways
- HVAC repair on a commercial system (see our commercial air conditioning guide) splits into what you can check and what needs a qualified person: anything that breaks into or tests the refrigerant circuit needs a qualified technician working for an F-gas certified company in Great Britain. Check power, controls and accessible filters yourself; leave the refrigerant side alone.
- We found one published commercial repair labour rate: Aspect’s “Half hour rates from £63.00 + VAT”, one hour minimum, in London and inside the M25. That is one provider’s price, not an average.
- Nobody we found publishes a price for a regas or a leak repair, so ask for a written quote that separates labour, parts and refrigerant.
- If a leak is found, GOV.UK says you “must repair it as soon as possible and repeat the test within a month”. While you wait, regulation 7 says the temperature in indoor workplaces “shall be reasonable”; on a maximum, HSE says “There’s no law for maximum working temperature, or when it’s too hot to work, because every workplace is different.”
First checks a business can safely do
For a failed unit in a shop or office, a person without F-gas qualifications can check that the power is on, that no breaker has tripped, that the controller’s settings and batteries are right, that nothing blocks the air inlets or outlets, and whether an accessible filter has clogged. Our table of what owners can do and what needs an engineer is in air conditioning repair, which is written for home units. Home-unit makers’ manuals say to stop the unit and call the installer if water leaks, the breaker trips or there is a burning smell, and the same caution applies at a larger scale. Do not open the casing or touch the refrigerant pipework. This page is part of our commercial air conditioning section.
Who can repair it
This is general information, not legal advice. GOV.UK (updated 3 March 2026) says that for stationary refrigeration, air conditioning and heat pump systems “you must have qualifications to” “install new systems”, “service and maintain systems”, “check for leaks”, “recover gases” and “decommission and dispose of old systems”. Its company certification page says your company “must be certified by an approved body to service stationary equipment containing F gas operated by others”, naming Refcom Certification Ltd, F-Gas Register (Quidos) and Bureau Veritas UK Ltd. Ask for the company’s certificate number and the engineer’s qualification before work starts. See F-gas regulations.
Refrigerant cannot be bought by just anyone. Article 11(4) of the F-gas Regulation as it applies in Great Britain says that for “installation, servicing, maintenance or repair”, F gases “shall only be sold to and purchased by undertakings that hold the relevant certificates” (or that employ certified people). Electrical faults and building work may also need other competent trades; in England, GOV.UK says “You do not need to get approval yourself if you use someone registered with a competent person scheme” where building regulations apply.
What a repair costs
Published labour rates
Aspect’s repair page says “Half hour rates from £63.00 + VAT”, with “One hour minimum”. It says parking, fuel or travel time, the Congestion Charge and ULEZ are not charged, and that parts and materials are extra. It covers all postcode districts within the M25. The page has no date; its footer shows 2026.
Our arithmetic from that rate:
- One hour minimum: 2 x £63 = £126 plus VAT, which is £151.20 with VAT at 20%.
- Each further half hour: £63 plus VAT = £75.60.
For emergency cooling, hire prices we found are Airconco’s £49.50 a week plus VAT for a 12,000 BTU portable, on a two-week minimum (£59.40 with VAT, our calculation), though its listing showed “Sold Out” on 25 November 2026. National Tool Hire lists a 16,000 BTU portable at £208.80 a week including VAT. These are single providers’ prices. VAT on hire at 20% is our reading, not a quotation from HMRC.
Prices nobody publishes
We found no published price for a regas, a leak repair or a recharge. For a home unit, BOXT’s page of May 2024 puts the average cost of replacing a compressor at “around £500” (one installer’s figure, for a home system, not a business one). A commercial compressor job will depend on the unit, so ask for a quote.
Maintenance contract or pay per visit
A contract can set your response time. Server Room Environments, an installer, says contracts come in tiers of “4 clock hours”, 8 working hours or 12 working hours, with call-out charges billed separately and covering “travel plus the first hour on site”; parts, parking, congestion and toll charges are extra. That is one installer’s description, not a standard. See HVAC maintenance and commercial air conditioning servicing.
Leaks: the legal side
GOV.UK’s page on checking F gas equipment says users of equipment and the technicians who maintain it share responsibility, and that if a leak is found you “must repair it as soon as possible and repeat the test within a month”. In Great Britain, leak checks are required from 5 tonnes CO2 equivalent (about 7.4 kg of R32): at least every 12 months, or 24 with a leak detection system; every 6 months from 50 tonnes, or 12 with one. Equipment of 500 tonnes or more must have a leak detection system and is then checked at least every 6 months (Articles 4 and 5). Article 6(2) says operators “shall keep the records” “for at least five years”. The charge at which each step starts, our arithmetic: tonnes CO2e = kg x GWP / 1,000.
| Refrigerant (GWP) | 5 tonnes | 50 tonnes |
|---|---|---|
| R32 (675) | 7.41 kg | 74.07 kg |
| R410A (about 2,088, US EPA table) | 2.39 kg | 23.95 kg |
The R410A figure is the US EPA’s, used here for illustration only; we did not check the figure the GB F-gas Regulation uses for this blend, so ask your engineer for the system’s CO2 equivalent. Find the charge on the outdoor unit’s rating plate. See air conditioning leaks and air conditioning gas.
Repair or replace
Old systems may hold refrigerants that can no longer be topped up with recycled gas. NetRegs, whose guidance is for businesses in Northern Ireland and Scotland, says “The use of recovered or reclaimed HCFCs to top up or service equipment has been banned since 1 January 2015”, and GOV.UK says “Reclaimed or recycled ODS cannot be used to service RACHP equipment in Great Britain” (published 18 April 2023; both checked 27 November 2026). Neither page names a specific refrigerant, so check the rating plate and ask your engineer what yours is and what the rules mean for it.
On new equipment, GOV.UK’s ban table (updated 27 August 2026) lists single split systems with less than 3 kg of refrigerant as banned “From 2025” (the law’s limit is a GWP of 750 or more), and “Larger air-conditioning or heat pump systems, such as chillers or larger split systems” among the exceptions. The bans are on placing new products on the market, and nothing in them requires a system already fitted to be removed. Age, parts availability and repair cost are the practical test; see replacing an air conditioning unit.
Heat in the meantime
Regulation 7 says the temperature in indoor workplaces “shall be reasonable”; on a maximum, HSE says “There’s no law for maximum working temperature, or when it’s too hot to work, because every workplace is different.” HSE’s steps include “Provide fans, such as desk, pedestal or ceiling-mounted ones”, “Provide air-cooling or air-conditioning and adequate ventilation”, shading, breaks and cold water. Hire is covered in air conditioning hire and commercial portable air conditioners. See workplace temperature law.
How to brief the engineer
- Give the make, model and refrigerant from the rating plate, and the age.
- Say what the fault code or display shows, exactly as shown, and when the problem started.
- Pass on the service history and F-gas records, including any earlier leak checks.
- Ask for a written quote that separates labour, parts, refrigerant and call-out, says what VAT is included, and states the engineer’s F-gas company certificate number.
Frequently asked questions
How much does an HVAC engineer charge per hour?
We found one published rate: Aspect’s “Half hour rates from £63.00 + VAT” with a one hour minimum, in London and inside the M25. Others quote per job.
Can any engineer repair air conditioning?
No. Work on the refrigerant circuit needs F-gas qualifications and a certified company in Great Britain.
How quickly should a commercial air conditioning repair happen?
Your contract sets it: one installer describes tiers from 4 clock hours to 12 working hours. The only legal timing we found is for a leak: “as soon as possible”, with a re-test within a month.
Is a refrigerant top-up a repair?
A top-up does not deal with the cause. GOV.UK says a leak found must be repaired as soon as possible and the test repeated within a month. See air conditioning gas.
Should I repair or replace an old system?
Check what refrigerant it holds. NetRegs says “The use of recovered or reclaimed HCFCs to top up or service equipment has been banned since 1 January 2015”, and GOV.UK says “Reclaimed or recycled ODS cannot be used to service RACHP equipment in Great Britain” (both checked 27 November 2026). Ask an F-gas certified engineer what can lawfully be done with your system.
What should I do if the office is too hot while I wait?
Regulation 7 says the temperature in indoor workplaces “shall be reasonable”; on a maximum, HSE says “There’s no law for maximum working temperature, or when it’s too hot to work, because every workplace is different.” HSE lists fans, air cooling, shading, water and breaks. Hire a portable unit if needed.
Sources
- Aspect: Air conditioning repairs (checked 25 November 2026)
- GOV.UK: Qualifications to work with F gas (updated 3 March 2026) (checked 25 November 2026)
- GOV.UK: Company certification to work with F gas (checked 25 November 2026)
- legislation.gov.uk: F-gas Regulation (EU) No 517/2014 as it applies in Great Britain, Article 11, with Articles 4, 5 and 6 (checked 25 November 2026)
- GOV.UK: Checking F gas equipment for leaks (checked 25 November 2026)
- GOV.UK: Bans on F gas in new products and equipment (updated 27 August 2026) (checked 25 November 2026)
- GOV.UK: Recovering ozone-depleting substances from equipment (published 18 April 2023) (checked 27 November 2026)
- NetRegs: Stationary refrigeration, air conditioning and heat pumps, ODS controls (checked 27 November 2026)
- US EPA: Technology Transitions GWP reference table (updated 2 April 2026) (checked 25 November 2026)
- Server Room Environments: Air conditioner maintenance contracts (checked 25 November 2026)
- Airconco: Amcor 3.5 kW (12,000 BTU) hire (checked 25 November 2026)
- National Tool Hire: Small portable air conditioner (checked 25 November 2026)
- BOXT: Air conditioning compressors (updated 24 May 2024) (checked 14 November 2026, as recorded in our installation cost data)
- HSE: Temperature in the workplace (updated 3 November 2026) (checked 27 November 2026)
- HSE: Managing workplace temperature (checked 25 November 2026)
- legislation.gov.uk: Workplace Regulations 1992, regulation 7 (checked 25 November 2026)
- GOV.UK: Building regulations approval, when you need approval (checked 25 November 2026)