Air conditioning leaks: refrigerant and water

By Editorial team. Updated 28 November 2026. Facts checked 25 November 2026.

Key takeaways

  • An air conditioning leak is one of two different faults. Water dripping from the indoor unit or its drain is condensate, covered on air conditioner leaking water. A refrigerant leak is a gas escaping from the sealed circuit, and only an F-gas qualified engineer may find, repair or recharge it. Our air conditioning repair guide covers the rest of repair and servicing.
  • You cannot smell refrigerant. Daikin says “the refrigerant inside the system is odourless” and Mitsubishi Electric says “refrigerants may not contain an odour”.
  • If you suspect a refrigerant leak, both makers say to stop using the unit and call the dealer. Daikin adds: turn off any combustible heating devices and ventilate the room.
  • In Great Britain, F-gas for servicing may be sold only to certified businesses (Article 11(4)), so a householder cannot lawfully buy refrigerant to top a system up.
  • The five tonne leak-check point is 7.41 kg of R32. The seven home systems in our product files hold 0.34 to 1.15 kg, 4.6% to 15.5% of that, but the duty to prevent leaks and repair them still applies. We found no published price for a leak repair.

Air conditioning leak is a phrase that covers two faults, and the first job is to tell them apart. This page is about the gas. For repairs in general, start with air conditioning repair and servicing; for drips, go to air conditioner leaking water.

Stop and switch off. Daikin’s operation manual for its FTXF-F room units says: “If water leaks from the unit. Stop the operation”, and, if the operation lamp flashes, “Notify your installer and report the error code.” Mitsubishi Electric’s MSZ-LN operating instructions (New Zealand edition) say to stop using the unit and consult your dealer “When water leaks or drips from the indoor unit”, “When the operation indicator lamp blinks”, “When the breaker trips frequently”, “When an abnormal sound is heard” and “When any refrigerant leakage is found.” These are two makers’ lists for named model families: use your own unit’s manual.

Is it water or refrigerant?

Water leak Refrigerant leak
What it is Condensate or drain water Gas escaping from the sealed refrigerant circuit
What you can see Drips or a wet patch at the indoor unit or drain Nothing to see, and no smell
What the makers say Daikin: stop the operation. Mitsubishi lists water from the indoor unit as a stop-and-consult case; it also says some water from the outdoor unit is normal (pipe condensation in cooling, defrost water in heating) Daikin: the refrigerant “is odourless”. Mitsubishi: “refrigerants may not contain an odour”

Two signs appear in the manuals we read. Mitsubishi’s says: “When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage.” Daikin’s E-series guide, for FTXF20 to FTXF42E5V1B units, lists “refrigerant shortage” among the error codes a wireless remote can show, and says reading and resetting codes “should be done by a licensed installer or your local dealer”. None of the manuals we read lists other signs, so we list none. A leak test by an engineer is how a leak is confirmed.

What to do if you suspect a refrigerant leak

Follow your own maker’s manual. Daikin’s FTXF-F manual, which names the 60 and 71 sizes, says the refrigerant “is mildly flammable, but normally does NOT leak”, and that if it leaks in the room and meets fire from a burner, heater or cooker, “this may result in fire, or the formation of a harmful gas”. It says to “Turn OFF any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit”, and: “Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired.”

Mitsubishi’s manual (New Zealand edition, MSZ-LN25VG2 to MSZ-LN60VG3) says: “If any refrigerant leakage is found, stop operations and ventilate the room well and consult your dealer immediately.” It calls the refrigerant “not harmful” but warns it creates “harmful gas” and “risk of fire” if it meets a fan heater, kerosene heater or cooking stove. We add no handling advice of our own.

Why you cannot fix a refrigerant leak yourself

GOV.UK says that for refrigeration, air conditioning and heat pump systems you must have qualifications to “install new systems”, “service and maintain systems”, “check for leaks” and “recover gases”, and the company must be certified by an approved body. In Great Britain, work on a split or other fixed system must be done by an F-gas qualified technician working for an F-gas certified company. Article 11(4) of the GB F-gas Regulation says F-gases for installation or servicing “shall only be sold to and purchased by undertakings” that hold the relevant certificates, so a householder cannot lawfully buy refrigerant to top up. Northern Ireland follows the EU F-gas system, so none of the Great Britain thresholds here apply there. More on F-gas regulations. This is general information, not legal advice.

What the law says about leaks

  • The duty. Article 3 says operators of equipment containing F-gases “shall take precautions to prevent” leakage, and where a leak is detected “the operators shall ensure that the equipment is repaired” “without undue delay”. We do not define who the operator is of a given home system; ask your installer.
  • Leak checks. Leak checks are required from 5 tonnes CO2 equivalent (about 7.4 kg of R32): at least every 12 months, or 24 with a leak detection system; every 6 months from 50 tonnes, or 12 with one. Equipment of 500 tonnes or more must have a leak detection system and is then checked at least every 6 months (Articles 4 and 5 of the GB Regulation). Where checks apply and a leak is found, you “must repair it as soon as possible and repeat the test within a month”.
  • Records. Article 6 says operators keep the records it covers for at least five years.

Our figure: where home systems sit against the 5 tonne point

Tonnes of CO2 equivalent are the charge in kg times the refrigerant’s global warming potential (GWP) divided by 1,000, the formula Daikin prints in its manual. R32’s GWP is 675 (Annex I of the GB Regulation). So 5 tonnes is 5,000 / 675 = 7.41 kg of R32.

System (charge from the maker’s table in our product file) R32 charge Tonnes CO2e Share of 7.41 kg
Toshiba Seiya 1.5 kW 0.34 kg 0.23 4.6%
Daikin Sensira 2.5 kW 0.42 kg 0.28 5.7%
Daikin Comfora 3.5 kW 0.70 kg 0.47 9.4%
Daikin Emura 2.5 kW 0.76 kg 0.51 10.3%
Mitsubishi Electric MSZ-LN25VG3 0.80 kg 0.54 10.8%
Daikin Perfera 2.5 kW 0.95 kg 0.64 12.8%
Daikin multi split 2MXM50A with two Perfera units 1.15 kg 0.78 15.5%

Every system listed is well under the point where the checking intervals start. That does not mean no rules apply: the Article 3 duty is separate. The charge is the maker’s figure for the system as sold; a long pipe run can need more, so ask your installer.

What an engineer will do

An engineer finds the leak, repairs it, tests, recharges and records what was done. iHeat, an installer, says: “Refrigerant should not be treated as a consumable that needs topping up every year”, and that a low charge needs “investigating rather than simply adding more refrigerant repeatedly.” We found no published price for a leak repair or recharge; the cost depends on finding the leak, the repair, recovering and recharging the gas, any parts and access. Ask for a written quote saying what is included and whether VAT is. Mitsubishi says: “If a repair involves recharging the unit with refrigerant, ask the service technician for details.”

Portable air conditioners

A portable’s refrigerant is also not the owner’s to handle. De’Longhi’s PAC AP manual says: “Transport, filling, cleaning, recovery and disposal of refrigerant should be performed by a technical service centre appointed by the manufacturer only.” Pro Breeze’s PB-AC04 manual says people who work on its R290 refrigerant circuit “must have the appropriate certification”, and that R290 “is odourless”. Check the maker’s warranty before anyone opens the unit.

Water leaks

If the leak is water, switch off, stop using the unit and read air conditioner leaking water. For what regassing means, see does home air conditioning need regassing? and air conditioning gas. Background on the gas is in our glossary entries for air conditioning refrigerant and R32 refrigerant.

Frequently asked questions

How do I know if my air conditioner has a refrigerant leak?

You cannot tell by smell or sight. Mitsubishi says poor cooling or heating means “there is a possibility of refrigerant leakage”, and Daikin’s E-series guide lists “refrigerant shortage” among its error codes. Only an engineer’s leak test confirms it.

Is an air conditioner refrigerant leak dangerous?

Daikin says R32 is mildly flammable and that a leak meeting a burner, heater or cooker “may result in fire, or the formation of a harmful gas”. Mitsubishi says the same about fire and harmful gas. Both say to stop using the unit and call the dealer.

Can I smell an air conditioner gas leak?

No. Daikin says “the refrigerant inside the system is odourless”, Mitsubishi that refrigerants “may not contain an odour”. A smell is not a sign of a leak: see air conditioner smells.

Can I fix an air conditioner refrigerant leak myself?

No. In Great Britain the work needs an F-gas qualified technician from a certified company, and refrigerant for servicing may be sold only to certified businesses. This is general information, not legal advice.

Who is responsible for repairing an air conditioning leak?

Article 3 puts the duty to repair “without undue delay” on operators of the equipment. Who that is for your system, and what your guarantee covers, are questions for your installer or seller; see the guarantee section of air conditioning repair and servicing.

What happens if I keep using an air conditioner with a leak?

Daikin says not to use the unit until a service person confirms the leak point has been repaired. Mitsubishi says to stop operations and consult the dealer.

Sources

  1. Daikin: FTXF60F2V1B and FTXF71F2V1B operation manual 3P511999-9S, 2024.09 (PDF) (checked 25 November 2026)
  2. Daikin: FTXF20 to 42E5V1B user reference guide 4D526466-14K, 2022.09 (PDF) (checked 25 November 2026)
  3. Mitsubishi Electric: MSZ-LN25VG2 to MSZ-LN60VG3 operating instructions VG79Y699H01, New Zealand edition (PDF) (checked 25 November 2026)
  4. De’Longhi: PAC AP series instructions for use 5715117836 (PDF) (checked 25 November 2026)
  5. Pro Breeze: PB-AC04 7000 BTU portable air conditioner instruction manual (PDF) (checked 25 November 2026)
  6. GOV.UK: Qualifications required to work on equipment containing F gas (updated 3 March 2026) (checked 25 November 2026)
  7. GOV.UK: Checking F gas equipment for leaks (published 21 August 2019) (checked 25 November 2026)
  8. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 3 (checked 25 November 2026)
  9. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 6 (checked 25 November 2026)
  10. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 11 (checked 25 November 2026)
  11. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Annex I (HFC-32 GWP 675) (checked 25 November 2026)
  12. iHeat: Air Conditioning Maintenance: Filter Cleaning, Servicing and Costs (updated 2 October 2026) (checked 25 November 2026; the address names a regassing article but opens this maintenance guide, which held the lines quoted when we looked again on 28 November 2026)
  13. Daikin UK: specifications tables RXF-F, RXM-A9, RXP-N9, RXJ-A9 and 2MXM-A8, for the R32 charges (checked 25 November 2026)
  14. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 4 (leak checks) (checked 25 November 2026)
  15. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 5 (leakage detection) (checked 25 November 2026)
  16. Toshiba Seiya 0.34 kg and Mitsubishi Electric MSZ-LN25VG3 0.80 kg: taken from our product files (Toshiba retail price list, effective 1 October 2026; Mitsubishi Electric UK product information sheet, effective February 2026), checked 14 November 2026. We could not re-open the Toshiba address on 25 November 2026 (it returned 404), and the Mitsubishi sheet’s charge did not read as text.

Products on this page

  • Daikin

    Sensira FTXF25F5V1B (indoor) with RXF25F5V1B (outdoor), 2.5 kW

    2.5 kW cooling · 40 dB · SEER 6.5

    No current UK price found

  • Daikin

    Perfera FTXM25A (indoor) with RXM25A5V1B9 (outdoor), 2.5 kW

    2.5 kW cooling · 41 dB · SEER 9.47

    No current UK price found

  • Daikin

    Multi split 2MXM50A2V1B8 (outdoor) with two Perfera FTXM25A indoor units, 5.0 kW

    5 kW cooling · SEER 8.53

    No current UK price found

Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.