Key takeaways
- A Daikin industrial air conditioner, as people search for it, means Daikin’s UK commercial ranges (part of our commercial air conditioning guide), which are Sky Air (which Daikin describes as the solution for “small to medium-sized commercial locations”), VRV for larger buildings, and chillers, air handling units and heat pumps from Daikin Applied UK.
- We found no “industrial” range under that name on the pages we opened: the commercial products serve shops, offices, hotels and larger buildings, and Daikin Applied lists data centres, hospitals, large offices and universities.
- Daikin UK publishes no commercial prices on the pages we opened; equipment is bought through installers, and refrigerant work needs an F-gas certified company.
- One Sky Air cassette, the 5 kW Round Flow FCAG60B with RZAG50B, has an annual cooling consumption of 252 kWh on Daikin’s table: about £72.04 a year at the small-business rate of 28.59p per kWh, excluding VAT.
Who Daikin is in the UK
Daikin UK’s about page says “Daikin Airconditioning UK Ltd is a wholly owned subsidiary of Daikin Europe NV.” Daikin Applied UK describes itself as “formerly McQuay UK Ltd”, located in Cramlington, Northumberland, with offices in Dartford, Kent. Its main product lines are “Air Handling Units, Chillers, and Heat Pumps”, for “large-scale bespoke projects, from data centres and hospitals to large offices and universities”.
This page covers commercial products only. For Daikin’s home range see Daikin air conditioners and Daikin heat pumps. It is part of our commercial air conditioning guide. We have not tested any of these products; everything below is from Daikin’s own pages, and any efficiency or saving figure is Daikin’s claim.
Sky Air: small and medium commercial
Daikin calls Sky Air “The energy efficient solution for small to medium-sized commercial locations” and names shops, offices and restaurants. It lists these indoor unit types:
- ceiling-mounted cassettes, including the Round Flow and Fully Flat cassettes;
- concealed ceiling units;
- wall-mounted units;
- ceiling-suspended units with a “Unique 4-way blow”;
- floor-standing units.
Daikin says its Bluevolution units use R-32 and describes the range as a heat pump that provides “heating in the winter and cooling in the summer”.
Example: the Round Flow cassette
Daikin’s FCAG-B page describes “360° air discharge”, a standard drain pump with 675 mm lift, an optional auto-cleaning filter panel and optional presence and floor sensors. It says the unit works with R-32 and R-410A outdoor units. Daikin’s table gives these figures:
| FCAG35B with RZAG35B | FCAG60B with RZAG50B | |
|---|---|---|
| Nominal cooling | 3.5 kW | 5 kW |
| Cooling range | 1.6 to 4.5 kW | 1.7 to 6 kW |
| SEER | 7.3 | 6.93 |
| Space cooling energy class | A++ | A++ |
| Annual consumption (cooling) | 168 kWh | 252 kWh |
Daikin’s table also has a row headed “Energy labeling Directive” that shows class A for both; we use the “Space cooling” class and consumption. The consumption figures are worked out on 350 hours of cooling a year.
VRV: Daikin’s variable refrigerant volume systems
Daikin’s VRV page is headed “Daikin VRV, invented by us” and calls it “The industry standard for total climate control”. Other makers call the same kind of system VRF; Designing Buildings says VRF suits buildings with many spaces and varying demand, such as hotels. Our guide to VRF air conditioning explains the technology. Daikin lists:
- VRV 5 Heat Recovery, with a “3-pipe heat recovery design” and simultaneous heating and cooling;
- VRV 5 Heat Pump, which it describes as “Flexible heat pump technology to fit any building, anywhere”;
- VRV 5 S-series, a low-height single fan range for R32 indoor units;
- VRV IV C+ series, which Daikin says gives “Reliable heating down to -25°C”;
- VRV IV I-series, a heat pump for indoor installation;
- Water-cooled VRV+ series, which Daikin calls “Ideal for high-rise buildings”.
Daikin Applied: chillers, air handling units and heat pumps
For large buildings, Daikin Applied UK supplies chillers (which remove heat from a liquid and feed chilled water to fan coil units and air handling units), air handling units and heat pumps. Daikin Applied says it is “the market leader in energy-efficient Air Handling Units”; that is its own claim, and it gives no source on the page. We did not open a Daikin Applied product page with figures, so we give none.
Air curtains and shops
Daikin’s Biddle air curtain page says the airflow “acts as a curtain that reduces heat loss and eliminates turbulence”. It makes claims of “72% more efficient than standard electric models” and that it can “reduce your heat loss by 80-85%”. Daikin gives no test method on the page, so treat them as claims. Its hotel page claims you can “Control up to 70% of your entire hotel’s energy use” with its controls; again, no method is stated. Our guide to hotel room air conditioning units covers room units.
How you buy Daikin commercial equipment
We found no prices on the Daikin commercial pages we opened. Equipment is sold through installers, and Daikin’s find an installer page lists trained D1 and D1+ partners (the page says Daikin “cannot be held responsible for any liability relating to their workmanship”, according to our brand file, checked 14 November 2026). Installing, servicing and leak checking refrigerant circuits must be done by a qualified technician working for an F-gas certified company in Great Britain. Compare the home-scale prices in Daikin air conditioner prices, and the home multi split range in Daikin multi split systems.
Warranty
Daikin’s installer warranty page (checked 25 November 2026) says D1 and D1+ partners get “Up to 7 years on AC equipment” and Certified Installers “Up to 5 years on AC equipment”, and sends readers to its Partner Portal for the terms. The terms are not public, so ask your installer for them in writing.
Running cost example
The domestic price cap does not apply to businesses, so use the unit rate on your own bill. As a guide this page uses DESNZ’s averages for April to June 2026, including Climate Change Levy and excluding VAT: 28.59p per kWh for small businesses (20 to 499 MWh a year) and 38.36p for very small ones (0 to 20 MWh). The running costs section of our commercial air conditioning guide explains the figures.
- 5 kW cassette (FCAG60B with RZAG50B): 252 kWh x 28.59p = £72.04 a year; at 38.36p, £96.67. Averaged over the label’s 350 hours, 252 / 350 = 0.72 kW.
- 3.5 kW cassette (FCAG35B with RZAG35B): 168 kWh x 28.59p = £48.03 a year; at 38.36p, £64.45. Average input 168 / 350 = 0.48 kW.
- Each extra 100 hours of cooling costs 72 kWh (£20.58 at 28.59p) for the 5 kW unit and 48 kWh (£13.72) for the 3.5 kW unit.
These are label figures for one indoor and one outdoor unit, not a building’s bill.
How to brief an installer
- Give room sizes, ceiling heights, people, equipment and hours of use.
- Ask for a heat load calculation and the make, model and SEER of every unit.
- Ask for the F-gas company certificate number, the warranty terms and what the price excludes.
- Ask for the refrigerant type and charge, for your F-gas records.
Frequently asked questions
Does Daikin make industrial air conditioners?
Daikin UK sells commercial Sky Air and VRV systems, and Daikin Applied UK makes chillers, air handling units and heat pumps for large projects such as data centres and hospitals. We did not find a range called industrial on the pages we opened.
What is Daikin VRV?
Daikin’s name for variable refrigerant flow, headed “Daikin VRV, invented by us” on its UK page. Daikin’s page uses “Variable Refrigerant Volume” in its control wording.
What is Daikin Sky Air?
Daikin’s heat pump range for small to medium commercial locations, with cassette, concealed, wall, ceiling-suspended and floor-standing indoor units.
Can I buy Daikin commercial units direct?
We found no public prices or online shop on the pages we opened. Daikin points buyers to trained partners, and refrigerant work needs an F-gas certified company.
Where are Daikin air handling units made?
Daikin Applied UK says it is located in Cramlington, Northumberland; its page does not say where each product is built.
Do Daikin commercial units heat as well as cool?
Daikin describes Sky Air as a heat pump that gives heating and cooling, and lists VRV 5 Heat Pump and Heat Recovery systems; its Heat Recovery page describes simultaneous cooling and heating.
Sources
- Daikin UK: About (checked 25 November 2026)
- Daikin Applied UK: About us (checked 25 November 2026)
- Daikin UK: Sky Air (checked 25 November 2026)
- Daikin UK: VRV (checked 25 November 2026)
- Daikin UK: Round Flow FCAG-B (checked 25 November 2026)
- Daikin UK: FCAG-B / RZAG-B technical details (checked 25 November 2026)
- Daikin UK: Biddle air curtains (checked 25 November 2026)
- Daikin UK: Hotels (checked 25 November 2026)
- Daikin UK: Installer warranty (checked 25 November 2026)
- Daikin UK: Find an installer (checked 14 November 2026, as recorded in our brand file)
- Designing Buildings: Variable refrigerant flow VRF (last edited 3 August 2021) (checked 25 November 2026)
- Designing Buildings: Chiller (last edited 16 December 2025) (checked 25 November 2026)
- GOV.UK: Company certification to work with F gas (checked 25 November 2026)
- DESNZ: Gas and electricity prices in the non-domestic sector (updated 29 September 2026), Table 3.4.2 including CCL, 2026 quarter 2 (page opened 25 November 2026; the quarter’s figures come from the linked table file, table_341.xlsx)
Products on this page
Daikin
Round Flow cassette FCAG60BVEB with Sky Air RZAG50B5V1B outdoor unit
5 kW cooling · SEER 6.93
No current UK price found
Daikin
Round Flow cassette FCAG35BVEB with Sky Air RZAG35B5V1B outdoor unit
3.5 kW cooling · SEER 7.3
No current UK price found
Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.