Key takeaways
- Searches for geothermal HVAC mostly lead to American pages. In UK sources the nearest match is ground source heating and cooling: a heat pump linked to fluid in a borehole or ground loop, or to groundwater.
- This is not an air-to-air heat pump. A ground source system heats water, and cools through fan coil units, passive beams or similar, according to Kensa. Our commercial air conditioning guide covers the air-based systems.
- Kensa says passive cooling, which bypasses the heat pump, has pumps and a fan as its only running cost, “can typically be around £20 per year” for its systems. That is a maker figure.
- In England, an open loop system needs a groundwater investigation consent and, above 20 cubic metres a day, an abstraction licence; a closed loop does not need either.
What “geothermal HVAC” means in the UK
We use “geothermal HVAC” here as the term American pages use for ground source heating and cooling, which is what the Environment Agency and Kensa pages we opened describe: systems that exchange heat with the ground or groundwater. We did not open a source on deep geothermal energy, which is a different technology, so this page does not cover it.
The Environment Agency’s 2024 summary says “it is thought that there are between 30,000 to 38,000 GSHC systems currently installed in the UK” (it notes the estimate is uncertain because records are incomplete), and puts larger non-domestic installations of more than 100 kW at “currently about 60 to 80” a year.
How a ground source system heats and cools
Closed loop and open loop
The Environment Agency says some systems use “fluid circulated within a borehole to exchange heat (closed-loop)” while “others abstract and reinject groundwater from an aquifer (open-loop)”.
Passive cooling: bypassing the heat pump
Kensa says in passive cooling the distribution system “bypasses the ground source heat pump and utilises the cooler temperature of the ground”, describing it as “ultra-low-cost cooling in the summer”.
Active cooling: chilled water
In active cooling, Kensa says the heat pump will “generate chilled water (typically at 6°C to 12°C) to cool the building”, working “in a similar manner to a chiller”. Designing Buildings says chillers “remove heat from a liquid through a refrigeration cycle”.
What delivers the cooling indoors
Kensa says the ground’s low temperature cools the property “via a fan coil, passive beams or other potential systems”. Our guide to fan coil units explains the room end of a water-based system. A ground source system therefore sits beside the chilled water systems in our VRF air conditioning and HVAC pages, not beside air-to-air units. For air-to-air units see how an air-to-air heat pump works and air-to-air versus air-to-water.
Permits and planning
This is general information, not legal advice. The permit rules below are for England; GOV.UK’s page links separate guidance for Northern Ireland, Scotland and Wales.
Open loop
GOV.UK (updated 19 November 2026) says “If you want to abstract groundwater, you must apply for consent to investigate a groundwater source”, and “You need an abstraction licence if you want to abstract (remove) more than 20 cubic metres per day”. Unless the system is low risk, you need “an environmental permit to discharge the water or a registered exemption from this requirement.”
Closed loop
GOV.UK says “You do not need groundwater investigation consent or an abstraction licence for a closed loop heat exchanger.” It adds that a discharge permit may still be required from 2 October 2023, so ask the Environment Agency about your site.
Planning
Planning Portal’s guidance for England says installing a ground or water source heat pump in the grounds of a non-domestic building “is likely to be considered ‘permitted development’”, with limits and conditions. It says air source heat pumps on non-domestic land “are likely to require an application” for planning permission. Wales, Scotland and Northern Ireland were not checked.
Grants
GOV.UK’s Boiler Upgrade Scheme page says “You can use the grant to replace a heating system in your home or a building used for your business” and that the scheme is open in England and Wales. The scheme’s grant of £7,500 for air-to-water or ground source heat pumps is in our rules data, checked 14 November 2026; we did not re-check the full eligibility rules for business buildings, so ask Ofgem or an MCS certified installer before you rely on it. The scheme’s regulation 9A says “An air-to-air heat pump is not an eligible plant in relation to a non-residential building”, so the grant does not help air-to-air units in a business. Our air-to-air heat pump grant guide has the home position.
Ground source against air-to-air for cooling
We found no independent comparison of running cost between ground source cooling and air conditioning, so we give none. Kensa describes passive cooling as “ultra-low-cost”, which is its own description. We found no published installed price for either option. See heat pump versus air conditioner.
What Kensa’s £20 means in electricity
Kensa’s “around £20 per year” is a cost in pounds; we turn it into units of electricity to show the scale. £20 is 2,000 pence. At the domestic price cap of 26.32p per kWh (Ofgem, Great Britain, 1 October to 31 December 2026) that buys 2,000 / 26.32 = 76.0 kWh. At the DESNZ small-business average of 28.59p per kWh (April to June 2026, including Climate Change Levy, excluding VAT) it buys 2,000 / 28.59 = 70.0 kWh. A business pays its own contract rate, not the domestic cap. This is what Kensa’s figure implies for its systems, not a guarantee for yours.
How to brief an installer
- Say what you need to cool as well as heat, and the loads for both.
- Ask who will survey the ground and whether a closed or open loop is proposed, and which permits that needs.
- Ask whether the installer is MCS certified, if you hope to claim a grant, and for the fan coil, beam or other equipment indoors.
- Ask for the running costs they assume, in kWh, and the source of the figure.
Frequently asked questions
Is geothermal the same as a ground source heat pump?
In the UK sources we opened, geothermal HVAC means ground source heating and cooling. We did not cover deep geothermal energy.
Can a ground source heat pump cool a building?
Yes. Kensa describes passive cooling that bypasses the heat pump and active cooling that makes chilled water.
Do I need a licence for a ground source heat pump?
In England, a closed loop needs no groundwater investigation consent or abstraction licence; an open loop needs consent to investigate and a licence above 20 cubic metres a day, plus a discharge permit or exemption unless low risk (GOV.UK, updated 19 November 2026).
Do I need planning permission for ground source heating on commercial premises?
Planning Portal says it is “likely to be considered ‘permitted development’” in the grounds of a non-domestic building in England, subject to limits. Ask the council.
Is there a grant for ground source heat pumps?
GOV.UK says the Boiler Upgrade Scheme (England and Wales) can be used for “a building used for your business”. The £7,500 grant for ground source heat pumps is from our rules data (checked 14 November 2026), and we did not check the conditions for business buildings. Ask Ofgem.
Is ground source cooling cheaper than air conditioning?
Kensa says passive cooling’s running cost can be around £20 a year; active cooling uses the heat pump like a chiller. We found no independent comparison.
Sources
- GOV.UK (Environment Agency): Environmental impacts of temperature changes from ground source heating and cooling systems, summary (6 September 2024) (checked 25 November 2026)
- Kensa: Active vs passive cooling (checked 25 November 2026)
- GOV.UK: Open loop heat pump systems, permits, consents and licences (updated 19 November 2026) (checked 25 November 2026)
- Planning Portal: Heat pumps, non-domestic (England) (checked 25 November 2026)
- GOV.UK: Apply for the Boiler Upgrade Scheme (checked 25 November 2026)
- legislation.gov.uk: Boiler Upgrade Scheme (England and Wales) (Amendment) Regulations 2026 (checked 14 November 2026, as recorded in our rules data)
- Designing Buildings: Chiller (last edited 16 December 2025) (checked 25 November 2026)
- Ofgem: Changes to the energy price cap between 1 October and 31 December 2026 (checked 13 November 2026, as recorded in our energy data)
- DESNZ: Gas and electricity prices in the non-domestic sector (updated 29 September 2026), Table 3.4.2 including CCL, 2026 quarter 2 (page opened 25 November 2026; figures from table_341.xlsx)