Key takeaways
- This Daikin air conditioner user guide follows Daikin’s own FTXF-F operation manual (document 3P511999-9S, September 2024) for the wireless remote that comes with its wall units. That file names only the 60 and 71 sizes, so check your unit’s label and download your own manual.
- The remote has five modes: Automatic, Drying, Heating, Cooling and Fan only. You cannot set a temperature in Drying or Fan only.
- Powerful runs for 20 minutes and then returns to your previous mode. Econo limits maximum power consumption by limiting compressor speed. Powerful, Econo and Comfort airflow cannot be used together.
- Wash or vacuum the filters about every 2 weeks. Never clean inside the unit: Daikin says that work is for a qualified service person.
- A flashing operation lamp means stop and report the error code to your installer.
Daikin’s wall-mounted split units, the Sensira range among them, come with a wireless remote. This guide explains daily use in plain words and says where each statement comes from. For the wider picture of repairs and servicing, see air conditioning repair and servicing; for the wired Madoka controller and the app, see Daikin controllers.
Which Daikin manual is this?
The statements below come from three Daikin documents, and each covers different models:
- FTXF-F operation manual 3P511999-9S, 2024.09 (the spine of this page): it names the FTXF60F2V1B and FTXF71F2V1B. The Sensira 2.5 kW in our product files is an FTXF25F5V1B, in the same F family, but this file does not name it. Your unit’s label decides which manual is yours.
- FTXF-E user reference guide 4D526466-14K, 2022.09: the earlier E series, sizes 20 to 42. We use it only for its symptom table and error code procedure.
- The manual itself says the detailed “User reference guide” is a digital file on daikin.eu, where you “use the search function to find your model”.
Starting and stopping
- Turn the circuit breaker on. Daikin says the flap of the indoor unit “will open and close to set the reference position”.
- Aim the remote at the indoor unit’s receiver. The maximum distance is 7 m. Curtains or other objects blocking the signal, direct sunlight on the remote, dust on the receiver and fluorescent lamps can all stop it working.
- Listen for the beeps: beep-beep, operation starts; one beep, a setting changes; a long beep, operation stops.
- If the remote is missing, the ON/OFF button on the indoor unit starts operation in Automatic mode at 25°C with automatic airflow.
Modes and temperature
| Mode | What Daikin says it does |
|---|---|
| Automatic | Cools or heats the room to the setpoint, switching between the two if necessary |
| Drying | “The system decreases the humidity in a room” |
| Heating | Heats to the setpoint |
| Cooling | Cools to the setpoint |
| Fan only | Controls only airflow rate and direction, not temperature |
You cannot set the temperature in Drying or Fan only. You cannot adjust the airflow rate in Drying. Daikin’s operating range table gives, for cooling, outdoor temperature minus 10 to 48°C dry bulb and indoor 18 to 32°C dry bulb. The same table prints “Indoor humidity: 80%” (as the text prints it; we cannot tell from the text whether it is a limit). It adds that “A safety device might stop the operation of the system if the unit runs outside its operation range”, and that “Condensation and water dripping might occur” outside the range for cooling. For drying, it gives indoor 18 to 32°C and outdoor minus 10 to 48°C. Our page on dry mode explains the idea.
Airflow, Comfort airflow, Powerful and Econo
- Airflow rate: five levels plus automatic, and a quiet setting that lowers noise from the unit.
- Direction: the vertical auto swing moves the flap up and down. Daikin says: “ALWAYS use a user interface (e.g. wireless remote control) to adjust the angle of the flap”, because moving it by hand “will break” the mechanism.
- Comfort airflow: the flap points up in cooling and down in heating, so the wind does not “come in direct contact with people”. It is not available in Fan only mode.
- Powerful: “quickly maximizes the cooling/heating effect”. It runs for 20 minutes, then returns to the previous mode, and can be set only while the unit is running.
- Econo: “limiting the maximum power consumption value”, by limiting the compressor’s rotation speed. Daikin says it is useful where a circuit breaker might trip when the unit runs alongside other appliances.
Powerful cannot be used with Econo or Comfort airflow. The last function you select takes priority.
Timers
The OFF timer can be set from 1 to 9 hours and the ON timer from 1 to 12 hours, one hour per press, and the two can be combined. With the OFF timer set, “Night set mode” raises the temperature setting by 0.5°C in cooling to avoid over-cooling. Daikin says to program the timers again after a breaker has turned the unit off, a power failure or new remote batteries.
Looking after it
- Filters: “It is recommended to clean the air filters every 2 weeks.” Steps and temperatures are on how to clean air conditioner filters.
- Batteries: two AAA batteries last about a year.
- Before a long idle period: run Fan only for several hours, turn the breaker off, clean the filters and take the batteries out.
- Inside the unit: “As an end user, you may NEVER clean inside parts of the unit by yourself; this work must be performed by a qualified service person.”
- Servicing: “Maintenance MUST be done by an authorised installer or service agent”, recommended at least once a year, and Daikin says costs “shall be borne by the customer”.
When to stop and call your installer
Daikin’s manual says to stop operation and shut off the power “if anything unusual occurs (burning smells etc.)”. If a fuse, breaker or earth leakage breaker frequently trips, turn off the main power; if water leaks from the unit, stop the operation; if the operation lamp flashes, “Notify your installer and report the error code.” It adds: “The system MUST be repaired by a qualified service person.” Refrigerant safety is covered in air conditioning leaks. Tell your installer the symptoms, “the complete model name of the unit” and the installation date. These are Daikin’s lists for named model families: use your own manual.
Our figure: what a Sensira costs to run
Daikin UK’s table gives the Sensira 2.5 kW (FTXF25F5V1B with RXF25F5V1B) an annual cooling consumption of 135 kWh. The energy label uses 350 hours of cooling a year for a split, so on average that is 135 / 350 = 0.386 kWh an hour. At 26.32p per kWh, Ofgem’s Great Britain average unit rate at the price cap for 1 October to 31 December 2026 (no VAT, 0%, for this period), that is 10.2p an hour, or 135 x 26.32p = £35.53 for the season. This is a label-based average for the 2.5 kW size, not the 60 or 71 size this manual covers, and the standing charge is left out. In Northern Ireland use the rate on your own bill. See the Daikin Sensira review and Daikin air conditioners.
Frequently asked questions
How do I use my Daikin air conditioner remote?
Aim it at the indoor unit (up to 7 m), press the mode button to choose Automatic, Drying, Heating, Cooling or Fan only, press ON/OFF to start, then use the temperature buttons. You cannot set the temperature in Drying or Fan only.
What do Powerful and Econo do on a Daikin air conditioner?
Powerful maximises cooling or heating for 20 minutes and then returns to the previous mode. Econo limits maximum power consumption by limiting compressor speed. They cannot be used together.
How often should I clean a Daikin air conditioner filter?
Daikin recommends every 2 weeks. If dust does not come off easily, it says to use a neutral detergent diluted in lukewarm water and to dry the filters in the shade.
Why is the operation lamp flashing on my Daikin air conditioner?
Daikin’s manual says that if the operation lamp flashes and you can check the error code on the remote, you should notify your installer and report the code. We print no code table: the full list is in the service manual, an engineer’s document.
How do I turn on my Daikin air conditioner without the remote?
Press the ON/OFF button on the indoor unit. It starts Automatic mode at 25°C with automatic airflow.
What temperature range can a Daikin air conditioner work in?
For the FTXF-F models in the manual, cooling is rated for outdoor temperatures of minus 10 to 48°C and indoor temperatures of 18 to 32°C. Heating is outdoor minus 15 to 24°C. A safety device might stop the unit outside the range.
Where can I download my Daikin manual?
Daikin’s manual points to daikin.eu: “Use the search function to find your model.” Quote your unit’s full model name, as shown on its label.
Sources
- Daikin: FTXF60F2V1B and FTXF71F2V1B operation manual 3P511999-9S, 2024.09 (PDF) (checked 25 November 2026)
- Daikin: FTXF20 to 42E5V1B user reference guide 4D526466-14K, 2022.09 (PDF) (checked 25 November 2026)
- Daikin UK: specifications table FTXF-F with RXF-F, for the 135 kWh annual cooling figure (checked 25 November 2026)
- Ofgem: Changes to energy price cap between 1 October and 31 December 2026 (checked 25 November 2026)
Products on this page
Daikin
Sensira FTXF25F5V1B (indoor) with RXF25F5V1B (outdoor), 2.5 kW
2.5 kW cooling · 40 dB · SEER 6.5
No current UK price found
Daikin
Sensira FTXF20F5V1B (indoor) with RXF20F5V1B (outdoor), 2.0 kW
2 kW cooling · 39 dB · SEER 6.5
No current UK price found
Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.