Sun, 29 Nov 2026What size do I need?

Air to air heat pump running costs against gas

By Editorial team. Updated 28 November 2026. Facts checked 15 November 2026.

Key takeaways

  • Air to air heat pump running costs depend on one number: its seasonal efficiency (SCOP); our air to air heat pump guide explains the system. At SCOP 5.2 a kWh of heat costs 5.1p; from a 90% efficient gas boiler it costs 8.9p.
  • The break-even is a seasonal efficiency of 2.97. Government modelling put real air to air systems at around 2.5 to 4; at 2.5 heat costs 10.5p per kWh, more than gas.
  • On its label, a Daikin Perfera 2.5 kW costs £170.29 a year to heat with, against £297.55 for the same heat from gas.
  • Keep the gas supply and you still pay its standing charge, £108.33 a year. DESNZ calls the immersion-heated hot water in its scenarios “less efficient”.
  • All figures are Great Britain averages at the Ofgem price cap for 1 October to 31 December 2026; they are not a promised saving.

The short answer

Air to air heat pump running costs for heating are lower than gas per unit of heat if the heat pump achieves a seasonal efficiency above about 3 in your home, and higher if it does not. A unit whose label SCOP is 5.2 delivers heat at 5.1p per kWh against 8.9p from a gas boiler. Whether a home sees that depends on the house, the installation and hot water. Our air to air heat pump guide explains the technology; this page is only the numbers.

The working: pence per kWh of heat

Compare the price of one kWh of heat: the fuel’s unit rate divided by its efficiency. Electricity is 26.32p per kWh and gas 7.97p per kWh (Ofgem’s Great Britain averages, Direct Debit, 1 October to 31 December 2026). Electricity carries no VAT (0%) for this period; gas carries 5%. Standing charges are left out of these per-kWh figures.

Gas boiler

A report for the Department for Energy Security and Net Zero (DESNZ), published 9 July 2026, modelled “combi-condensing gas boilers around 0.9:1” (heat out to energy in). So 7.97p / 0.9 = 8.9p per kWh of heat. A new gas boiler in an English home must reach a product label efficiency of 92% under Boiler Plus (“The new minimum performance standard for domestic gas boilers in English homes will be set at 92% ErP”); at 92% the heat costs 8.7p. That is a label figure, so we treat it as gas’s best case. We have no sourced figure for older boilers, so we do not give one.

Heat pump at its SCOP

SCOP is the seasonal coefficient of performance on the energy label, worked out over a standard heating season. We use the “average” climate figure each time; that season is designed around -10C outside and counts 1,400 heating hours a year (Regulation 626/2011, Annex VII).

SCOP (average climate) or modelled ratio Example Pence per kWh of heat
5.2 Daikin Perfera 2.5 kW; Mitsubishi Electric MSZ-LN25VG3 5.1p
4.6 Toshiba Seiya 2.5 kW (Toshiba’s 2026 retail price list (updated 17 November 2026), as read on 28 November 2026); electriQ iQool 9000 5.7p
4.4 Fujitsu ASYG12KMCC 6.0p
4.2 Bosch Climate 3200i 3.5 kW; Daikin Sensira 2.5 kW 6.3p
4.0 DESNZ’s upper modelled figure 6.6p
2.5 DESNZ’s lower modelled figure 10.5p
0.9 Gas boiler (DESNZ) 8.9p

Working, once: 26.32p / 5.2 = 5.06p, shown as 5.1p.

The break-even SCOP

26.32p / 8.856p = 2.97. A heat pump that achieves a seasonal efficiency above 2.97 in your home costs less per kWh of heat than a 90% gas boiler at these prices; against a 92% boiler the break-even is 3.04. This is our arithmetic from Ofgem’s rates.

A year of heating for named units (label method)

Where a maker gives the label’s annual heating consumption, the yearly cost is that figure times 26.32p. The heat delivered is the design load (Pdesignh) times 1,400 hours. We then work out the gas needed for the same heat at 90%.

Worked example: Daikin’s table gives the Perfera 2.5 kW 647 kWh a year at a 2.40 kW design load and SCOP 5.20. 647 x 26.32p = £170.29. Heat: 2.4 kW x 1,400 h = 3,360 kWh. Gas: 3,360 / 0.9 = 3,733.3 kWh x 7.97p = £297.55. Difference: £127.26.

Unit SCOP Label heating use Electricity cost Heat delivered Same heat from gas at 90% Same heat at efficiency 2.5
Daikin Perfera 2.5 kW 5.2 647 kWh £170.29 3,360 kWh £297.55 £353.74
Fujitsu ASYG12KMCC 4.4 795 kWh £209.24 3,498 kWh £309.77 £368.27
Bosch Climate 3200i 3.5 kW 4.2 833 kWh £219.25 3,500 kWh £309.94 £368.48

Bosch’s data sheet gives a 2.5 kW design load. Fujitsu’s specification gives no design load in the part we could read, so its heat is our arithmetic: 795 kWh x SCOP 4.4 = 3,498 kWh. The last column shows the same heat if the system only achieved DESNZ’s low figure of 2.5: then all three cost more than gas. These label years assume a design load of about 2.5 kW; your home’s comes from a heat-loss calculation.

Real life against the label

A label SCOP is a test result. DESNZ’s modelling, with supplementary electric heaters, found the ratio of useful space heating to energy used “varied from around 2.5:1 to around 4:1”, against “between 3:1 and 3.5:1” for air-to-water heat pumps, and says the uncertainty for air to air is higher. The same report found “a RAAHP system always requires less energy than a direct electric heating system”. It used the April to June 2026 cap rates (24.67p and 5.74p), so we quote its ratios, not its pounds. Nesta’s study of 16 households, which it says is not representative, found “Homeowners were satisfied with running costs and the comfort”. Neither is a measured UK average. See air to air heat pump efficiency.

Standing charges: if you keep gas, if you go all electric

Per-kWh figures leave standing charges out. But if you remove the boiler and cap the gas, you stop paying the gas standing charge: 29.68p a day, £108.33 a year (29.68p x 365). If you keep gas for hot water or cooking, you keep paying it. The electricity standing charge (54.83p a day) is paid either way. Keeping the boiler alongside also rules out the Boiler Upgrade Scheme grant: Ofgem’s guidance says a funded system “must fully replace the property’s existing fossil fuel or electric heating system”, apart from permitted non-fossil supplementary appliances (3.75). The grant is £2,500 in England and Wales since 28 April 2026, but when we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed. See air to air heat pump cost for what each source says must be replaced.

Hot water costs

MCS says “many air-to-air heat pumps do not provide hot water”. DESNZ found that in most of its scenarios “hot water was provided by a less efficient immersion heated tank”, and that this limits the picture of operating costs. An immersion heater runs on electricity at 26.32p per kWh; we found no source in our reading that gives its efficiency, so we do not convert that into a cost per kWh of hot water. If an air to air heat pump replaces a gas boiler that heated your water, this cost can eat into the heating saving.

Cooling costs in summer

The energy label applies 350 hours of cooling a year to split systems. The Perfera 2.5 kW’s label gives 92 kWh: £24.21 a year. The Bosch Climate 3200i 3.5 kW uses 182 kWh: £47.90. See air conditioning running costs and is air conditioning expensive to run.

Tariffs

Octopus Energy’s Cosy Octopus tariff is for homes with “a heat pump (air or ground source), an electric boiler or electric radiators”. It has three cheaper periods (04:00 to 07:00, 13:00 to 16:00 and 22:00 to 00:00) that Octopus says are 51% cheaper than the day rate in your region, and a 16:00 to 19:00 peak 50% above it. The page gives no unit rates and does not mention air to air heat pumps, so we could not confirm that an air to air home qualifies; ask Octopus. Running costs on any time-of-use tariff depend on when the heat pump runs.

Northern Ireland

The Ofgem price cap covers England, Scotland and Wales only. In Northern Ireland, use the unit rate on your own bill and divide it by the SCOP, as above.

Try your own figures in our running cost calculator. Related: air to air heat pump cost, using air conditioning for heating and solar powered air conditioning.

Frequently asked questions

Is an air to air heat pump cheaper to run than a gas boiler?

Per kWh of heat, yes if its seasonal efficiency in your home is above about 3: at SCOP 5.2 heat costs 5.1p against 8.9p from a 90% gas boiler. At DESNZ’s low figure of 2.5 it costs 10.5p, more than gas.

What SCOP do I need to beat gas?

2.97 against a 90% efficient gas boiler, or 3.04 against a 92% boiler, at the October to December 2026 cap.

How much does it cost to run per hour?

It varies with output, and an inverter unit often draws less once the room is up to temperature. A label year is a better guide: £170.29 for a Daikin Perfera 2.5 kW.

Will I still pay the gas standing charge?

Only if you keep a gas supply, for example for hot water or cooking: £108.33 a year at the October to December 2026 cap.

Is it cheaper than storage heaters?

DESNZ’s modelling found an air to air system “always requires less energy than a direct electric heating system”. Its comparison is with direct electric heating in general, not storage heaters on an off-peak tariff, and we have not costed those here, so we give no pound figure.

Sources

  1. Ofgem: Energy price cap unit rates and standing charges (checked 15 November 2026)
  2. DESNZ: Understanding the suitability of reversible air-to-air heat pumps for domestic use in the UK (9 July 2026, PDF) (checked 15 November 2026)
  3. GOV.UK (BEIS): Boiler Plus factsheet (PDF) (checked 15 November 2026)
  4. legislation.gov.uk: Regulation (EU) No 626/2011, Annex VII (checked 15 November 2026)
  5. Daikin UK: FTXM-A and RXM-A9 specifications table (checked 15 November 2026)
  6. Worcester Bosch: Climate 3200i 3.5 kW energy data sheet (PDF) (checked 15 November 2026)
  7. GENERAL (Fujitsu): ASYG KMCC specifications (PDF) (checked 15 November 2026)
  8. Mitsubishi Electric UK: MSZ-LN R32 product information sheet (PDF) (checked 15 November 2026)
  9. Toshiba’s 2026 retail price list (GBP edition, updated 17 November 2026) (checked 28 November 2026)
  10. Appliances Direct: electriQ iQool9Plus (checked 15 November 2026)
  11. Daikin UK: FTXF-F and RXF-F specifications table (Sensira) (checked 15 November 2026)
  12. MCS: Air-to-air heat pumps (checked 25 November 2026)
  13. Nesta: Air-to-air heat pumps, a low carbon solution for UK homes (17 February 2026) (checked 15 November 2026)
  14. Octopus Energy: Cosy Octopus (checked 25 November 2026)
  15. Ofgem: Boiler Upgrade Scheme, Guidance for Installers V5.2 (PDF) (checked 25 November 2026)

Products on this page

  • Daikin

    Perfera FTXM25A (indoor) with RXM25A5V1B9 (outdoor), 2.5 kW

    2.5 kW cooling · 41 dB · SEER 9.47

    No current UK price found

  • Bosch

    Climate 3200i CL3200i-Set 35 WE (7733703596), 3.5 kW

    3.6 kW cooling · 56 dB · SEER 7

    No current UK price found

  • Fujitsu

    ASYG12KMCC (indoor) with AOYG12KMCC (outdoor), 3.4 kW

    3.4 kW cooling · 40 dB · SEER 7.3

    No current UK price found

  • Mitsubishi Electric

    MSZ-LN25VG3 (indoor) with MUZ-LN25VG3 (outdoor), 2.5 kW

    2.5 kW cooling · 42 dB · 485 W · 13p an hour

    No current UK price found

  • Toshiba

    Seiya RAS-B10S4KVG-E (indoor) with RAS-10E2AVG-E (outdoor), 2.5 kW

    2.5 kW cooling · 39 dB · SEER 7

    No current UK price found

  • electriQ

    iQool 9000 BTU Smart A+++ Wall Mounted Split Air Conditioner with Heat Pump, 5m pipe kit (iQool9Plus)

    9,000 BTU · 660 W · 17p an hour · 26 m²

    £429.98 at Appliances Direct, checked 14 Nov 2026

    See it at Appliances Direct
  • Daikin

    Sensira FTXF25F5V1B (indoor) with RXF25F5V1B (outdoor), 2.5 kW

    2.5 kW cooling · 40 dB · SEER 6.5

    No current UK price found

Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.