Sun, 29 Nov 2026What size do I need?

Heat pump air conditioners: units that heat and cool

By Editorial team. Updated 25 November 2026. Facts checked 15 November 2026.

Key takeaways

  • A heat pump air conditioner is an air conditioner that can run its cycle in reverse and heat. In law and in makers’ brochures it is an air-to-air heat pump: see our guide to air to air heat pumps.
  • Look for a heating capacity in kW, a SCOP (seasonal heating efficiency) and a heating energy class on the spec sheet. A cooling-only unit has none of them.
  • At a SCOP of 5.2, heat costs 5.1p per kWh against 8.9p from a 90% efficient gas boiler, at the October to December 2026 price cap. At a SCOP of 4.2 it costs 6.3p.
  • Whether a unit heats changes the rules: planning in England, VAT and the grant all treat it differently from a unit that only cools.

This is general information, not legal advice.

What makes an air conditioner a heat pump?

A heat pump air conditioner is a split air conditioner whose refrigerant cycle can run both ways. Daikin UK describes the cooling cycle in four steps (compress, condense, expand, evaporate) and says that to understand a heat pump you “simply apply this same four-step process in reverse” (Daikin UK). In cooling mode the indoor unit takes heat out of the room. In heating mode the outdoor unit takes heat from the outside air and the indoor unit releases it into the room. Our how it works page has the steps.

The law uses the same idea. The 2026 Boiler Upgrade Scheme regulations describe a heat pump as a plant that “generates heat using a thermodynamic cycle”, and an air-to-air one as using that energy “to heat air for the purposes of space heating” (S.I. 2026/390). Makers use both names. Daikin’s UK brochure says “Daikin air-to-air heat pumps deliver heating, cooling, and clean air in a single, intelligent, energy-efficient system” (Daikin UK brochure, October 2025). Worcester Bosch sells the Climate 3200i as an air conditioning unit and describes “Heating, cooling, dehumidifying, and purifying from a single unit”; its page does not call it a heat pump (Worcester Bosch).

For the wider picture, see heating and cooling air conditioners, heat pump vs air conditioner and our split air conditioner guide.

How to tell whether a unit heats

Heating capacity and heating at -7C

The spec sheet should give a heating capacity in kW as well as a cooling one. The Daikin Perfera 2.5 kW lists a nominal heating capacity of 2.80 kW (Daikin UK specifications). Some makers also print the output at -7C outdoors; the Bosch Climate 3200i 3.5 kW data sheet gives 2.2 kW at -7C (Worcester Bosch data sheet, checked 14 November 2026). Daikin’s table for the Perfera does not give a figure at -7C: it points to a separate drawing for the operating range. If your home needs heat on the coldest days, ask for the output at your area’s design temperature.

SCOP and the heating energy class

SCOP is the seasonal coefficient of performance: the heat the unit delivers over a heating season divided by the electricity it uses. The legal energy label tests heating in an “average”, “warmer” or “colder” climate and counts 1,400 hours of heating a year for average and warmer, 2,100 for colder (Regulation 626/2011, Annex VII). The UK sheets we read quote the average climate, so write “SCOP (average climate)”. The same Annex gives a separate cooling-only line at 350 hours, which is why a cooling-only unit has a cooling class and no heating one. The Perfera 2.5 kW has a SCOP of 5.20 and heating class A+++; the Bosch 3.5 kW has 4.2 and A+ (average climate), and 3.4 in the colder one (Worcester Bosch data sheet).

A label SCOP is a test result, not a promise for your home.

Why it matters: planning, VAT and the grant

  • Planning, England: Class G allows an outdoor unit under permitted development only if it is “not solely used for the purpose of cooling” and meets the size, number and noise limits (Class G). A unit that heats, or heats and cools, can go up without a planning application if it meets those limits; one that only cools needs permission. Whether a heat-and-cool unit used mainly for cooling meets the condition is for the council to judge. See planning permission.
  • VAT: HMRC says “most air conditioning units are air source heat pumps”, and zero-rates a fixed one installed in a home to 31 March 2027, then 5%; portable units do not qualify and supply without installation is standard-rated (HMRC Notice 708/6). A cooling-only unit may not qualify. See VAT on air conditioning.
  • Grant: the Boiler Upgrade Scheme has offered £2,500 towards an air-to-air heat pump in England and Wales since 28 April 2026, with conditions on what heating the heat pump replaces and who fits it: see the grant section of our air to air heat pump guide. When we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed (MCS). It is not for air conditioning used only for cooling. See the air to air heat pump grant.

What it costs to heat with one

At the Ofgem price cap for 1 October to 31 December 2026 (26.32p per kWh of electricity, with no VAT (0%) for this period, and 7.97p for gas; Ofgem), heat from a unit with a label SCOP of 5.2 costs 5.1p per kWh and from one at 4.2 costs 6.3p, against 8.9p from a gas boiler at the “around 0.9:1” that DESNZ modelled (DESNZ report, July 2026). DESNZ modelled real air-to-air systems as low as around 2.5, where heat costs 10.5p, more than gas, so none of this is a promised saving; in Northern Ireland, use the unit rate on your own bill. The full working, the break-even and a worked year for a named unit are in air to air heat pump running costs and air to air heat pump efficiency.

Examples from makers’ documents

We have not tested any unit; these are makers’ published figures.

  • Daikin Perfera 2.5 kW: heating 2.80 kW, SCOP 5.20, A+++, 647 kWh a year for heating.
  • Mitsubishi Electric MSZ-LN25VG3: heating 3.2 kW, SCOP 5.2, A+++ (product information sheet recorded in our product file, checked 14 November 2026); Mitsubishi Electric UK titles the range an “Inverter Heat Pump” (Mitsubishi Electric UK).
  • Bosch Climate 3200i 3.5 kW: SCOP 4.2, A+, 2.5 kW design load, 2.2 kW at -7C.

Frequently asked questions

Is an air conditioner a heat pump?

A split air conditioner that can heat is an air-to-air heat pump: the same machine, run in reverse. A cooling-only unit is not, and cannot heat.

Do all air conditioners heat?

No. Check the spec sheet for a heating capacity and SCOP. Some units, such as many portables, have no heat mode, and some fixed ones are sold as cooling only.

Is heating with air conditioning expensive?

Per kWh of heat, a unit with a SCOP of 5.2 costs 5.1p against 8.9p from a 90% gas boiler at the October to December 2026 cap. Below a seasonal efficiency of about 3 it costs more than gas.

What does SCOP mean?

Seasonal coefficient of performance: heat delivered over the heating season for each unit of electricity used, tested to the energy label’s rules.

Does a heat pump air conditioner need planning permission?

In England, not if it heats (or heats and cools) and meets the Class G limits, including the MCS 020 a) noise calculation. A unit used solely for cooling does. Wales, Scotland and Northern Ireland have their own rules.

Sources

  1. MCS: Air-to-air heat pumps (checked 25 November 2026)
  2. legislation.gov.uk: S.I. 2026/390 (checked 15 November 2026)
  3. legislation.gov.uk: Regulation 626/2011, Annex VII (checked 15 November 2026)
  4. Daikin UK: The refrigerant cycle (checked 15 November 2026)
  5. Daikin UK: Residential air-to-air heat pumps brochure (UKEPCEN25-1205, October 2025) (checked 15 November 2026)
  6. Daikin UK: FTXM-A and RXM-A9 specifications table (checked 15 November 2026)
  7. Worcester Bosch: Climate 3200i single split (checked 15 November 2026)
  8. Worcester Bosch: Climate 3200i 3.5 kW energy data sheet (2025/04) (checked 14 November 2026)
  9. Mitsubishi Electric UK: MSZ-LN R32 (checked 14 November 2026)
  10. legislation.gov.uk: Class G, General Permitted Development Order 2015 (checked 15 November 2026)
  11. HMRC: VAT Notice 708/6 (checked 15 November 2026)
  12. DESNZ: Understanding the suitability of reversible air-to-air heat pumps for domestic use in the UK (9 July 2026, PDF) (checked 15 November 2026)
  13. Ofgem: Energy price cap unit rates and standing charges (checked 15 November 2026)

Products on this page

  • Daikin

    Perfera FTXM25A (indoor) with RXM25A5V1B9 (outdoor), 2.5 kW

    2.5 kW cooling · 41 dB · SEER 9.47

    No current UK price found

  • Bosch

    Climate 3200i CL3200i-Set 35 WE (7733703596), 3.5 kW

    3.6 kW cooling · 56 dB · SEER 7

    No current UK price found

  • Mitsubishi Electric

    MSZ-LN25VG3 (indoor) with MUZ-LN25VG3 (outdoor), 2.5 kW

    2.5 kW cooling · 42 dB · 485 W · 13p an hour

    No current UK price found

Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.