Key takeaways
- Air source heat pump air conditioning means two different machines. An air to air heat pump (a split air conditioner that heats) cools by running in reverse, so cooling is part of its design. An air-to-water one heats water for radiators; some models list cooling, but how that cooling reaches your rooms is something to ask the installer.
- Daikin UK lists “heating and cooling” for its Altherma 3 R W and cooling for its mid-temperature Altherma 3 H MT sets; its pages do not say how the cooling is delivered.
- Octopus Energy announced a Cosy Cooler for 2027: a unit that connects to the radiator pipework of an existing Cosy heat pump, at £500 to £600 added to a Cosy system, against £2,000 to £6,000 for traditional air conditioning on Octopus’s own figures.
- Cooling is the cheap half of a heat pump’s year: on its label a Daikin Perfera 2.5 kW uses 92 kWh a year to cool, £24.21 at the October to December 2026 price cap.
- A heat pump used only for cooling does not qualify for the grant and is not covered by England’s permitted development right for heat pumps.
The short answer
Yes, some can. This page answers the question for anyone who has, or is planning, an air source heat pump and wants it to double as air conditioning. Our air to air heat pump guide covers the machine that does both jobs by design; this page covers what an air-to-water owner can do, and where the two meet.
| Air to air | Air to water | |
|---|---|---|
| What it heats | Room air | Water for radiators and hot water |
| How it cools | Runs in reverse and blows cool air from the indoor units | Some models list cooling; how it is delivered is not stated on Daikin’s pages |
| Add-on for cooling | None needed | Octopus’s Cosy Cooler (2027), for Cosy heat pumps |
| Where to read more | Air to air guide | Daikin Altherma |
Air to air: built for cooling as well as heating
An air-to-air heat pump moves heat between the air outside and the air inside, and most can run both ways: a split air conditioner with a heat mode is one, as our pillar guide explains. If your main need is a cool bedroom, this is the route that needs no extra equipment. See split air conditioners and how air to air heat pumps compare with plain air conditioners.
Air to water: cooling through pipes (some models)
An air-to-water heat pump heats water, and cooling is not a given. Daikin UK’s range page for its Altherma air-to-water heat pumps describes its low-temperature sets as able to “cool, heat and provide hot water”, and its mid-temperature sets as giving heating, cooling and domestic hot water. If you own a different make, check the maker’s own documents; we have not looked at any other air-to-water range.
What Daikin says for Altherma 3 R W
Daikin UK’s Altherma 3 R W page lists “heating and cooling”, hot water up to 60C with an optional 150 to 300 litre tank, operation down to -25C and an outdoor unit of 44 to 50 dBA. It does not say how the cooling is delivered to the rooms, how much cooling it gives or what it costs to run. The Altherma 3 R F page lists “heating, cooling and hot water” with a built-in 180 litre tank, again without capacities.
Why radiators are not designed for cooling
We found no maker or government page we could open that says whether ordinary radiators can be used to cool a room, so we do not claim either way. Ask your installer in writing which emitters, if any, are meant to carry chilled water in your system, and what happens if they are not. Octopus’s Cosy Cooler (next section) exists as a separate fan unit on the pipework, which is one sign that cooling is treated as its own job, but that is our reading, not Octopus’s statement.
Octopus Cosy Cooler: a fan unit on the radiator pipes (2027)
Octopus Energy’s press release, dated 14 October (the page shows no year), describes a unit that “plugs directly into radiator pipework to circulate chilled water through the home”. Octopus says:
- It is “the size of a tall kitchen bin” and needs no outdoor hose.
- It draws in warm room air, cools it with a heat exchanger and blows it back; the heat travels through the heating pipework to the outdoor Cosy heat pump.
- It costs “£500-600” when added to an existing Cosy heat pump system, takes about three hours to install and is “available in 2027”.
- Traditional air conditioning costs “£2,000 to £6,000” to install.
Our arithmetic on Octopus’s own figures: £500 is 8% of £6,000 and £600 is 30% of £2,000, so the Cosy Cooler costs between about 8% and 30% of Octopus’s range for traditional air conditioning, if you already have a Cosy heat pump. The figure is Octopus’s announcement, not a price list. See Octopus and air to air heat pumps and Octopus air conditioning installation.
Planning and the grant if you also want cooling
Planning in England: an air source heat pump can be installed under permitted development if it meets the limits, including the condition that it “is not solely used for the purpose of cooling” (Class G). The installation must comply with MCS 020 a), which checks a limit of 37 dB LAeq,5mins at nearby assessment positions (MCS 020 a)). If you plan to use a unit mostly for cooling, ask your council. See planning permission.
The grant: the Boiler Upgrade Scheme has offered £2,500 towards an air-to-air heat pump in England and Wales since 28 April 2026 (£7,500 for air-to-water or ground source), but it is only for a heat pump that replaces the home’s existing heating and can heat the whole home, fitted by an MCS certified installer (Ofgem installer guidance V5.2, paragraphs 1.06, 3.75, 3.80 and 3.89). When we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed. What must be replaced: Ofgem’s guidance says a fossil fuel system or an electric heating system that does not include a heat pump (3.37); GOV.UK says “fossil fuel heating systems - such as oil, gas, electric or LPG”; MCS’s page says “the replacement of a fossil fuel heating appliance”. A system bought only for cooling does not qualify. See our air to air heat pump grant guide.
Ground source systems are a different technology; see geothermal HVAC.
What cooling costs to run
On the energy label, split systems are rated for cooling over 350 hours a year (Regulation 626/2011, Annex VII). Our working, using the label’s yearly cooling energy and 26.32p per kWh, Ofgem’s Great Britain average electricity rate for 1 October to 31 December 2026, which carries no VAT (0%) for this period (Ofgem):
| Unit | Label cooling use a year | Cost at 26.32p |
|---|---|---|
| Daikin Perfera 2.5 kW | 92 kWh | £24.21 |
| Bosch Climate 3200i 3.5 kW | 182 kWh | £47.90 |
92 kWh x 26.32p = £24.21, and 182 kWh x 26.32p = £47.90. These are label figures for a mild test, not your bill: your own use depends on the room, the weather and how long it runs. In Northern Ireland, use the unit rate on your own bill. We have not tested either unit. Cooling in an air-to-water system has no figure on Daikin’s pages, so we give none.
Frequently asked questions
Can an air source heat pump cool my house?
An air-to-air one can: cooling is built in. An air-to-water one may, depending on the model; Daikin lists cooling for some Altherma sets but does not say how it reaches the rooms.
Can I use my radiators for cooling?
We found no maker or government source that says. Ask your installer in writing which parts of your system are meant to carry chilled water.
What is the Octopus Cosy Cooler?
A unit about the size of a tall kitchen bin that plugs into the radiator pipework of an existing Cosy heat pump and cools a room. Octopus says it is £500 to £600, takes about three hours to fit and is available in 2027.
Will cooling stop me getting a grant?
Cooling on its own cannot qualify, because the grant is for a heat pump that replaces your heating. A system that also heats can qualify if it meets the scheme’s rules, but when we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed.
Does an air source heat pump need planning permission?
In England, not if the outdoor unit meets the permitted development limits and the MCS 020 a) noise limit, and it is not solely used for cooling. Wales, Scotland and Northern Ireland have their own rules.
Sources
- Daikin UK: Air-to-water heat pumps (checked 15 November 2026)
- Daikin UK: Daikin Altherma 3 R W (checked 15 November 2026)
- Daikin UK: Daikin Altherma 3 R F (checked 15 November 2026)
- Octopus Energy: New low cost add-on will turn heat pumps into air cons (checked 15 November 2026)
- Daikin UK: specifications table FTXM-A and RXM-A9 (Perfera) (checked 15 November 2026)
- Worcester Bosch: Climate 3200i 3.5 kW energy data sheet (PDF) (checked 15 November 2026)
- legislation.gov.uk: Regulation (EU) No 626/2011, Annex VII (checked 15 November 2026)
- legislation.gov.uk: Class G, Town and Country Planning (General Permitted Development) Order 2015 (checked 15 November 2026)
- MCS: MCS 020 a) Issue 1.1 (PDF) (checked 15 November 2026)
- MCS: Air-to-air heat pumps (checked 25 November 2026)
- GOV.UK: Apply for the Boiler Upgrade Scheme (printable guide) (checked 15 November 2026)
- Ofgem: Boiler Upgrade Scheme, Guidance for Installers V5.2 (PDF) (checked 25 November 2026)
- Ofgem: Energy price cap unit rates and standing charges (checked 15 November 2026)
Products on this page
Daikin
Perfera FTXM25A (indoor) with RXM25A5V1B9 (outdoor), 2.5 kW
2.5 kW cooling · 41 dB · SEER 9.47
No current UK price found
Bosch
Climate 3200i CL3200i-Set 35 WE (7733703596), 3.5 kW
3.6 kW cooling · 56 dB · SEER 7
No current UK price found
Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.