Key takeaways
- Air cooler repair starts with a check on the weather: “not cooling” can be humidity, not a fault. An air cooler does little in muggy air and adds moisture to a closed room, so check the weather and open a window before you look for a fault.
- The steps below are for the Pro Breeze OmniAir 7L (PB-AC06), the one manual we could read in full. Other makers differ: check your own manual.
- Pro Breeze’s manual says to unplug the cooler and empty the tank before cleaning, and not to “attempt to repair or adjust any electrical or mechanical elements”.
- A tank of water costs next to nothing (about 0.16p an hour in mains water by our working); a repair is worth it only if it costs less than a replacement.
Is it broken, or is it humid?
An air cooler cools by evaporation, so it depends on dry air. On a hot, dry afternoon (30C, 40% humidity) the air leaving a cooler could at best be about 7 to 9C cooler. On a humid day (30C, 60%) at best 4.5 to 5.6C, and in muggy air (25C, 75%) about 2.5 to 3C. That is the air at the outlet, with all water in the air it adds to the room. Those figures are our own calculation. In muggy air a cooler that works can feel as if it does nothing. The Met Office says that when the air is saturated “no further evaporation can occur” [1]. See do evaporative air coolers work in the UK? for the figures and how air coolers work for the mechanism.
Honeywell’s listing at B&Q says its cooler “will require a flow of air like an open window and/or door in the room to work effectively” [8]. So before anything else: open a window, check it is a dry spell, and give it time.
What you need
- Your manual. This page quotes the Pro Breeze OmniAir 7L manual (PB-AC06, February 2023) [2]. No other maker’s manual could be read in full.
- A soft cloth, a vacuum cleaner with a brush attachment, warm water and mild washing-up liquid. Pro Breeze says to clean the tank “with warm tap water and mild detergent (e.g. washing up liquid)” and not to use boiling water or “any abrasive cleaners or solvents” [2].
- The cooler switched off and unplugged, with the tank emptied. Pro Breeze’s warning: “ALWAYS TURN THE APPLIANCE OFF, UNPLUG THE POWER CORD FROM THE ELECTRICAL OUTLET AND EMPTY THE WATER TANK BEFORE HANDLING, CLEANING OR SERVICING THE APPLIANCE” [2].
Step-by-step fixes
It is not cooling
- Check the water. The OmniAir 7L manual says the water must be above the “min” mark for humidification mode to work, and that if the water drop symbol flashes “there is insufficient water in the tank” [2].
- Check the mode. On that model, cooling by water is “Humidification Mode”, switched on with its own button, and it “can be activated in any of the modes” [2]. If the water drop symbol is not showing, the manual’s description of humidification mode (evaporating water from the tank) does not apply.
- Check the filters. The manual says “Do not use the appliance without the air filter” and that the filter “should be cleaned every two weeks using a damp cloth” [2]. Dust from the air filter can be vacuumed with the brush attachment.
- Check the air. The manual says the appliance “must have a minimum 50cm clearance around all sides” [2]. Open a window or door.
- Think about the air: if it is humid, a cooler may be working and still do little, and a fan or an air conditioner is the alternative; see fan vs air cooler.
No water reaches the pad, or the pump is silent
The OmniAir 7L manual has no troubleshooting table and does not describe its pump, so we cannot give model-specific pump steps. What it does say: the tank is “connected to the device” and should not be forced; on its base “there is a clip that connects the filter to the tank”; and the tank should be pushed fully back and the lock clipped [2]. Check the tank is seated and the clip is fastened. Symphony’s customer care page for its air coolers lists “The water pump doesn’t work” as a query and tells you to contact customer care, with no steps [4]. Its maintenance page lists cleaning “the submersible pump impeller” and the “water distribution pipe/channels” as work for a service [5]. Pro Breeze’s manual says “Do not attempt to repair or adjust any electrical or mechanical elements in the appliance. Doing so may be unsafe and will void your warranty” [2]. If the pump stays silent after you have checked the water and the tank, contact the maker or retailer.
It smells, or the water looks cloudy
The OmniAir 7L manual says “There may be trace of odour during the first few minutes of initial use. This is normal.” Beyond that: “Always empty the water tank, clean and dry the appliance when not in use to prevent mould”, and “Ensure fresh water is added to the water tank prior to every use” [2]. To clean the tank, per the manual: remove and empty it, wash with warm tap water and mild detergent, “remove any scale or deposits that have formed inside the water tank”, and “Wipe all surfaces dry before placing the water tank back” [2]. Symphony’s customer care page says for odour: “Change the water regularly”, keep the pads clean and, to clean the pad, “unplug the cooler and apply low water pressure with the help of a pipe on the cooling pad”, at least once or twice a year [4]; that is Symphony’s general advice for its own air coolers, not a manual for a UK model. A smell that returns after cleaning is a reason to stop using the cooler and ask the maker.
It leaks
The OmniAir 7L manual says: “Always place the appliance in an upright position on a flat, stable surface. Operating the product in any other position could cause a hazard and leakages”; “Do not remove the water tank when the appliance is in use, this may cause water to leak”; “Do not fill the water tank over the max line or below the min line”; and, with ice packs, “Condensation may form on the outside of the water tank … which can drip onto the floor” [2]. Check the level, the surface and the tank position. Never let water run into the unit: “DO NOT ALLOW WATER OR OTHER LIQUIDS TO RUN INTO THE INTERIOR OF THE APPLIANCE, AS THIS COULD CREATE A FIRE AND/OR ELECTRICAL HAZARD” [2]. If it leaks from inside the body, unplug it and do not use it.
The remote or display does not respond
The OmniAir 7L manual says the remote works “within five metres from the front of the device” and must point “to the LED display”; it takes two AAA batteries, fitted with the right polarity; and “Remove exhausted battery promptly” [2]. Replace the batteries and aim at the display. It also warns: “If the battery compartment does not close securely, stop using the product” [2].
How to clean and maintain it
From the OmniAir 7L manual [2]:
- Switch off, unplug and empty the tank.
- Wipe the outside with a soft, damp cloth and dry it.
- Clean the vents and openings “regularly with a vacuum cleaner, using the brush attachment”.
- Clean the filter every two weeks with a damp cloth.
- Clean the tank as above and dry it.
- Before storage: “Empty and clean the appliance before storage” and keep it “in a safe, clean and dry place”.
Pad replacement: the OmniAir 7L manual gives no steps for replacing its honeycomb evaporative filter, so we cannot give them. Symphony’s maintenance page says “Yearly change of cooling pad provides optimum cooling” for its air coolers [5]. Honeywell’s 10L listing at B&Q says “no replacement filters are needed” for that model [8]. Check your own manual.
Hygiene and safety
We found no HSE, UKHSA or NHS page about domestic portable coolers. What the official sources say is general. The NHS says Legionnaires’ disease “is usually caught in places like hotels, hospitals or offices where the bacteria have got into the water supply”, and lists “air conditioning systems” and “humidifiers” among things you can catch it from; it is less common to catch it at home [6]. HSE’s guidance is for workplaces: it says any water system is potentially a reasonably foreseeable legionella risk if the water temperature may be “between 20-45°C” or it stores or re-circulates water, and that systems that present a risk “should be maintained in a clean state and monitored” [7]. HSE’s evaporative cooling page covers cooling towers and evaporative condensers and does not mention small coolers [9]. We do not say a home cooler is a risk or that it is safe. Stored water that may sit between 20 and 45°C is a condition HSE names, so follow the maker’s cleaning and emptying advice. Unplug before cleaning and never open the electrical parts. The same manual says “Never leave the appliance unattended while in use” and “This appliance is intended for indoor household use and similar applications” [2].
Repair or replace?
- Prices in our library. The home coolers with a stated power that we found with a price ran from £79.99 (Symphony Duet Desk, Eco Wizard, checked 25 November 2026 [14]) to £199.99 (Igenix IG9750 at Homebase, out of stock when we checked 25 November 2026 [15]); a 70 litre industrial unit was £419.99 at B&Q. See air cooler prices. The Pro Breeze OmniAir 7L was £149.99 and out of stock at Pro Breeze when we checked on 14 November 2026; the page would not open on 25 November 2026.
- Warranty first. Listings we opened on 25 November 2026: Mylek 8L, two years (B&Q); Honeywell 10L, a 1-year guarantee (B&Q); electriQ Arctic 25, a 12-month guarantee (Appliances Direct); Maha Kool 70L, a 1-year guarantee (B&Q) [8, 10, 11, 12]. Pro Breeze’s manual says repairs by you “will void your warranty” [2]. Pro Breeze states no warranty length in the sources we could read.
- No repair prices. We found no UK provider’s page that states a price to repair a home air cooler, so we give none. Ask for a quote and compare it with the cost of a new unit.
- Running costs are low. At 65 W the OmniAir 7L’s electricity costs 1.7p an hour (0.065 kWh at 26.32p per kWh, Ofgem’s Great Britain price cap average for 1 October to 31 December 2026 [3]; no VAT, 0%; in Northern Ireland use your own bill’s rate). Water adds about 0.16p an hour: 0.8 litres an hour (the manual’s evaporative rate) at CIBSE’s 2018 figure of about £2 per cubic metre of mains water (our working) [13]. A 7 litre tank lasts about 8.75 hours at that rate. So the economics of repair are about the purchase price, not the running cost.
For more on cooler maintenance by brand, see Pro Breeze air coolers; for staying cool while a unit is out of action, see the UK heatwave guide.
Frequently asked questions
Why is my air cooler not cooling?
Humidity can be the reason: in muggy air an evaporative cooler can do very little [1]. Then check the water level, the mode, the filter and an open window, as above.
Why does my air cooler smell?
Standing water and damp surfaces. The OmniAir 7L manual says to empty the tank, clean and dry the appliance when not in use “to prevent mould”, and a first-use odour that fades is normal [2].
How often should I clean an air cooler?
Pro Breeze’s manual says the filter “should be cleaned every two weeks” and to empty and dry the appliance when not in use [2]. Symphony says to clean its pads at least once or twice a year [4]. Follow your own manual.
Can I use tap water?
The OmniAir 7L manual says “fresh water” for the tank and does not say whether tap, filtered or distilled water is better; it uses “warm tap water” for cleaning the tank [2]. Check yours.
Why is my air cooler leaking?
Check the tank, the water level and the surface it stands on first: see the leak steps above. Do not use it if water gets inside.
How do I replace the cooling pad?
That depends on the model. The OmniAir 7L manual gives no steps; Symphony recommends a yearly pad change for its coolers [5]. Use your own manual.
Is a smelly air cooler dangerous?
We found no HSE, UKHSA or NHS page about domestic coolers. Official sources say water stored or re-circulated at 20 to 45°C is a legionella risk factor in workplaces [7], and the NHS says it is less common to catch Legionnaires’ disease at home [6]. Clean and dry the cooler as the maker says, and ask the maker if you are unsure how.
Sources
- Met Office: What are wet bulb temperatures and what they are used for? (7 August 2025) (checked 25 November 2026)
- Pro Breeze: OmniAir 7L (PB-AC06) instruction manual, February 2023 (checked 25 November 2026)
- Ofgem: Changes to energy price cap between 1 October and 31 December 2026 (checked 25 November 2026)
- Symphony: Troubleshooting air coolers, customer care (checked 25 November 2026)
- Symphony: Preventive maintenance for air coolers (checked 25 November 2026)
- NHS: Legionnaires’ disease (checked 25 November 2026)
- HSE: Other systems that can create a risk of legionella (checked 25 November 2026)
- B&Q: Honeywell 10L evaporative air cooler 3 in 1 (checked 25 November 2026)
- HSE: Evaporative cooling systems (checked 25 November 2026)
- B&Q: Mylek 8L evaporative air cooler (checked 25 November 2026)
- Appliances Direct: electriQ Arctic 25 air cooler (checked 25 November 2026)
- B&Q: Maha Kool 70L industrial evaporative cooler (checked 25 November 2026)
- CIBSE Journal: Module 135, Direct evaporative cooling for comfort applications (Tim Dwyer, November 2018) (checked 25 November 2026)
- Eco Wizard: Symphony Duet Desk evaporative air cooler (checked 25 November 2026)
- Homebase: Igenix white evaporative air cooler 50L (checked 25 November 2026)
Products on this page
Pro Breeze
OmniAir 7L Evaporative Air Cooler (PB-AC06)
65 watts · 64 dB · 2p an hour · 7 L tank
£149.99 at Pro Breeze (maker shop), checked 14 Nov 2026
See it at Pro Breeze (maker shop)
Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.