Sun, 29 Nov 2026What size do I need?

BTU room calculator UK: what air conditioner size?

By Editorial team. Updated 14 November 2026. Facts checked 14 November 2026.

Key takeaways

  • BTU room calculator UK answers: a typical double bedroom (4 x 3.5 m) needs 4,777 BTU, so 5,000 BTU. A 5 x 4 m living room needs 6,824 BTU, so 7,000 BTU, or 10,000 BTU if it faces the sun and four people use it.
  • A sun-facing 4 x 4 m loft bedroom needs 7,370 BTU, so 8,000 BTU. A 4 x 3 m kitchen needs 4,913 BTU, so 5,000 BTU.
  • A 4 x 3.5 m conservatory with a 2.5 m average height needs 6,469 BTU, so 7,000 BTU.
  • The answer is always rounded up to the next size sold, and it is cooling only: do not use it to size a radiator.

This BTU room calculator for UK homes is the quick version of our full BTU calculator. You choose a room type, enter the length and width in metres or feet, and it tells you the air conditioner size to buy in BTU and kW. The full calculator has more options, the sourcing for every figure, and a radiator mode for heating.

Room size calculator

The rule in one line: cooling needed in watts = room volume in cubic metres x 100 / 2.4, adjusted for the room type, then x 3.412141 for BTU per hour.

How the tool will work: choose the room type, enter the two floor measurements in metres or feet, leave the ceiling at 2.4 m unless yours differs, and read the answer in BTU, kW and the size to buy. Each room type applies the right adjustment for you. A “more options” link goes to the full calculator for sun, loft, insulation and people.

id: btu-room-calculator-uk
page: /tools/btu-room-calculator-uk/
data: data/energy.json (sizing)
mode: cooling only

inputs:
  units:         { type: choice, options: [metres, feet], default: metres }
  roomType:      { type: choice, options: [bedroom, living room, loft bedroom, kitchen, conservatory, open-plan room, other], default: bedroom }
  length:        { type: number, min: 0.5, max: 50, unit: m or ft, required: true }
  width:         { type: number, min: 0.5, max: 50, unit: m or ft, required: true }
  ceilingHeight: { type: number, min: 1.5, max: 6, unit: m or ft, default: 2.4 m (7.87 ft); conservatory default 2.5 m }

room type presets (percent from sizing.adjustments; people default 2):
  bedroom: 0 | living room: 0 | loft bedroom: loftOrTopFloor 20 | kitchen: 20 | conservatory: 30 | open-plan room: 0 | other: 0
  (sun, insulation and extra people are set on the full calculator, linked as "more options")

conversion of feet:
  metres = feet x 0.3048 (exact); convert each dimension before multiplying.

formula:
  volumeM3 = length x width x ceilingHeight
  needW    = volumeM3 x 100 / 2.4 x (1 + percent / 100)    # use 41.6667 unrounded
  needBtu  = needW x 3.412141
  needKw   = needW / 1000

rounding (sizing.rounding):
  sizes = [5000, 7000, 8000, 9000, 10000, 12000, 14000, 15000, 16000, 18000, 20000, 24000]
  recommended = smallest size >= needBtu; below 5000 recommend 5000
  above 24000: "No single home unit covers this room: consider two units or ask an installer for a heat-load survey."
  display needBtu to the nearest 100, needKw to 2 decimals

output wording:
  "Your room needs about {needBtu} BTU per hour ({needKw} kW) of cooling. Buy {recommended} BTU or larger.
   If it is a single-hose portable, check the maker's own room size as well, and go up a size if it does not cover your room."

no JavaScript: the table below gives the same answers for common rooms.

What size air conditioner for each room?

Every row uses a 2.4 m ceiling unless stated, two people, and the rule above. The feet are the same room converted at 0.3048 m to the foot.

Room Size in metres (feet) Volume Cooling needed BTU per hour Size to buy
Box room 2.5 x 2.5 m (8 ft 2 in x 8 ft 2 in) 15.0 m3 625 W 2,133 5,000 BTU
Single bedroom 3 x 3 m (9 ft 10 in x 9 ft 10 in) 21.6 m3 900 W 3,071 5,000 BTU
Double bedroom 4 x 3.5 m (13 ft 1 in x 11 ft 6 in) 33.6 m3 1,400 W 4,777 5,000 BTU
Living room 5 x 4 m (16 ft 5 in x 13 ft 1 in) 48.0 m3 2,000 W 6,824 7,000 BTU
Living room, sun-facing, four people 5 x 4 m 48.0 m3 2,660 W 9,076 10,000 BTU
Loft bedroom, sun-facing (+35%) 4 x 4 m (13 ft 1 in square), 2.4 m average 38.4 m3 2,160 W 7,370 8,000 BTU
Kitchen (+20%) 4 x 3 m (13 ft 1 in x 9 ft 10 in) 28.8 m3 1,440 W 4,913 5,000 BTU
Conservatory (+30%) 4 x 3.5 m (13 ft 1 in x 11 ft 6 in), 2.5 m average 35.0 m3 1,896 W 6,469 7,000 BTU
Open-plan room, poorly insulated, three people 6 x 5 m (19 ft 8 in x 16 ft 5 in) 72.0 m3 3,480 W 11,874 12,000 BTU

How one row is worked: the sun-facing living room is 5 x 4 x 2.4 = 48 m3, so 48 x 41.6667 = 2,000 W. Sun adds 15%: 2,300 W. Two extra people add 180 W each: 2,660 W. 2,660 x 3.412141 = 9,076 BTU, so 10,000 BTU. The rule is Daikin UK’s “around 0.1 kW per square metre”, scaled by volume, with the adjustments set out in the full calculator. Electric Point’s guide gives the same advice on rounding: “Always round up, never down.”

The sizes sold are 5,000, 7,000, 8,000, 9,000, 10,000, 12,000, 14,000, 15,000, 16,000, 18,000, 20,000 and 24,000 BTU. See our pages on 5,000, 7,000 and 12,000 BTU for the units at each size, how many BTU you need and what size air conditioner you need. For specific rooms: bedrooms, conservatories, loft conversions and garages.

Measuring your room

  • Metres or feet: measure wall to wall at floor level. Convert feet to metres by multiplying by 0.3048 (exact); 13 ft 1 in is about 4.0 m. Work out the volume in metres first.
  • Ceiling height: 2.4 m (7 ft 10 in) is the standard. A higher ceiling needs proportionally more: Daikin UK says a 3 m ceiling raises the volume by 25%, “and so should your cooling capacity”. The 4 x 3.5 m double bedroom moves from 5,000 BTU to 7,000 BTU at 3 m.
  • Sloping ceilings: use the average height. A 4 x 4 m loft room that slopes from 1.5 m at the eaves to 2.7 m at the ridge averages 2.1 m: 33.6 m3, 1,400 W, plus 20% for the loft = 1,680 W = 5,732 BTU, so 7,000 BTU.
  • L-shaped rooms: split it into rectangles, work out each volume and add them. A 5 x 3 m section plus a 2 x 2 m section at 2.4 m is 19 m2 of floor and 45.6 m3, so 1,900 W = 6,483 BTU, so 7,000 BTU.
  • Open doors: if the room opens to another one, measure both as one.

Frequently asked questions

What size air conditioner do I need for a 3 x 3 m bedroom?

A 3 x 3 m bedroom at a 2.4 m ceiling has 21.6 m3 and needs 3,071 BTU, which is below the smallest size sold, so 5,000 BTU. If it is in a loft or faces the sun, the answer is still 5,000 BTU (about 4,100 BTU with both adjustments).

What BTU for a 20 m2 room?

At a 2.4 m ceiling, 20 m2 is 48 m3 and needs 2,000 W, which is 6,824 BTU, so 7,000 BTU. With sun it needs 7,848 BTU, so 8,000 BTU. At a 3 m ceiling, 20 m2 needs 8,530 BTU, so 9,000 BTU.

How do I measure a room with a sloping ceiling?

Use the average ceiling height across the room. For a loft that slopes from 1.5 m to 2.7 m, use 2.1 m, then add 20% for the loft in the calculation.

Can one unit cool two rooms?

Not well. A single unit cools the room it is in. If two rooms are open to each other, size for both as one space. If a door is closed between them, the other room gets little cooling, and a multi-split system (one outdoor unit, two indoor units) is the usual way to cool two rooms.

Is the answer different for a portable?

The size is the same, but a single-hose portable cools less than its rated BTU suggests, because the rating does not count the warm air that leaks in to replace what the hose exhausts. Check the maker’s own room size and go up a size if it does not cover your room.

Sources

  1. Daikin UK: air conditioner size guide (checked 14 November 2026)
  2. Electric Point: portable air conditioning units UK buying guide (checked 14 November 2026)
  3. NIST: Guide for the use of the SI, Appendix B.9, factors for units listed by kind of quantity (checked 14 November 2026)
  4. Federal Register: DOE test procedures for portable air conditioners, 1 June 2016 (checked 14 November 2026)