Sun, 29 Nov 2026What size do I need?

BTU to kWh converter: energy, not power

By Editorial team. Updated 14 November 2026. Facts checked 14 November 2026.

Key takeaways

  • 1 kWh is 3,412.14 BTU of energy, so kWh = BTU x 0.000293.
  • “12,000 BTU” on an air conditioner is BTU per hour, which is power, not energy. Running it for one hour moves 12,000 BTU of heat, which is 3.52 kWh of heat.
  • The kWh you pay for is the electricity used, not the heat moved. The Meaco Cirro 12000 moves 3.52 kWh of heat an hour and uses 1.35 kWh of electricity, costing 35.5p.
  • A “BTU to kWh” answer needs a time: multiply BTU per hour by the hours, then divide by 3,412.14.

The answer in one line: divide BTU by 3,412.14 to get kWh. If the figure is BTU per hour, multiply by the hours the unit runs first.

This page converts BTU to kWh. If you came from our BTU calculator wanting power instead, use BTU to kW.

BTU to kWh converter

Enter an amount of energy in BTU, or in kWh, and the tool returns the other. For BTU per hour, there is a second mode that asks how many hours the unit runs.

id: btu-to-kwh
page: /tools/btu-to-kwh/
data: data/energy.json (sizing.conversions, priceCap, assumptions)

inputs:
  mode:      { type: choice, options: [btuToKwh, kwhToBtu, btuPerHourOverHours], default: btuToKwh }
  value:     { type: number, min: 0, required: true, unit: BTU, kWh, or BTU per hour }
  hours:     { type: number, min: 0.1, max: 8760, default: 1, shownWhen: mode == btuPerHourOverHours }
  inputPowerWatts: { type: number, min: 0, optional: true, shownWhen: mode == btuPerHourOverHours, label: "Rated electrical input of the unit, in watts (optional)" }

formula:
  btuToKwh:            kwh = value / sizing.conversions.btuPerKwh                      # 3,412.14
  kwhToBtu:            btu = value x sizing.conversions.btuPerKwh
  btuPerHourOverHours: heatKwh = value x hours / sizing.conversions.btuPerKwh
  if inputPowerWatts given:
    electricityKwh = inputPowerWatts / 1000 x hours
    costPence      = electricityKwh x priceCap.pence                                 # 26.32 until energy.json changes

rounding:
  kWh to 2 decimal places (1 decimal for electricityKwh); BTU to the nearest 1; cost to 1 decimal of a penny under 100p, else pounds to 2 decimals

output wording:
  btuToKwh: "{value} BTU is {kwh} kWh of energy."
  btuPerHourOverHours: "{value} BTU per hour for {hours} hours moves {heatKwh} kWh of heat."
  if inputPowerWatts: "That unit uses {electricityKwh} kWh of electricity, costing about {cost} at {priceCap.pence}p per kWh (Great Britain average, {priceCap.from} to {priceCap.to})."
  always add: "Heat moved is not electricity used. These figures use the Great Britain price cap. In Northern Ireland, use the unit rate on your own bill."

no JavaScript: the formula and worked examples below give the same answers.

The formula

A kilowatt hour is 3,600,000 joules, exactly. A BTU is 1,055.056 joules (NIST SP 811, Appendix B.9). So one kWh is 3,600,000 / 1,055.056 = 3,412.14 BTU, and one BTU is 0.000293 kWh.

  • kWh = BTU / 3,412.14
  • BTU = kWh x 3,412.14

BTU and BTU per hour are not the same

BTU is a quantity of energy, like a litre of petrol. BTU per hour is a rate, like litres per minute: it is power. An air conditioner labelled “12,000 BTU” has a cooling power of 12,000 BTU per hour. It does not “contain” 12,000 BTU. Likewise kW is power and kWh is energy.

So “BTU to kWh” has two possible meanings. If you have an amount of energy in BTU, divide by 3,412.14. If you have a unit’s BTU per hour, you cannot convert it to kWh without a time: multiply by the hours it runs first. And even then you get kWh of heat moved, not the kWh on your bill. For the conversion that gives power, see BTU to kW or BTU to watts; for the definition, what BTU means.

How many kWh does an air conditioner use?

Two different kWh figures apply to the same hour of running.

Heat moved. The Meaco Cirro 12000 is rated at 12,000 BTU per hour. In one hour that is 12,000 BTU of heat taken out of the room, and 12,000 / 3,412.14 = 3.52 kWh of heat.

Electricity used. Meaco rates it at 1,350 W, which is 1.35 kW, so one hour uses 1.35 kWh. At 26.32p per kWh, the Ofgem price cap for 1 October to 31 December 2026 (Great Britain average), that is 35.5p an hour. For our standard 350-hour summer, 1.35 kW x 350 hours is 472.5 kWh, which is £124.36.

The unit moves more heat than the electricity it uses because it is a heat pump: it carries heat out rather than making it. The ratio, 3.52 / 1.35, is about 2.6. Meaco’s own label gives 2.7, from a rated cooling capacity of 3.5 kW and a measured 1.3 kWh an hour. These figures use the Great Britain price cap. In Northern Ireland, use the unit rate on your own bill. They leave out the standing charge, and rated power is a full-power figure. For a unit-by-unit method see air conditioning running costs and the running cost calculator. For how heat pumps do this, see how air conditioning works.

Heating: from a radiator’s BTU to kWh

Radiator output is also given in BTU per hour. Viessmann UK’s example is a 4.8 x 4 x 2.4 m bedroom, 46.08 m3, which at 108 BTU per cubic metre needs 4,977 BTU per hour. Run for one hour, that is 4,977 / 3,412.14 = 1.46 kWh of heat. A central heating boiler’s gas use, or an electric radiator’s electricity, depends on its efficiency, so the kWh on the bill is not simply that figure. The cooling rule must not be used for radiators; see our BTU calculator radiator mode.

Frequently asked questions

How many BTU are in a kWh?

3,412.14 BTU. A kWh is 3,600,000 joules and a BTU is 1,055.056 joules, so one kWh is 3,412.14 BTU.

How do I convert BTU to kWh?

Divide the BTU by 3,412.14. For example 10,000 BTU is 2.93 kWh. If you have BTU per hour, multiply by the number of hours first.

Is BTU per hour the same as kWh?

No. BTU per hour is power, like kW. kWh is energy, like BTU. A unit with 12,000 BTU per hour of cooling gives 3.52 kW of power, and over one hour moves 3.52 kWh of heat.

How many kWh does a 12,000 BTU air conditioner use?

The Meaco Cirro 12000 uses 1.35 kWh of electricity for each hour at full power, which is 472.5 kWh over 350 hours. Other 12,000 BTU units draw similar power, but check each one’s rated input in watts.

Why is the heat moved more than the electricity used?

An air conditioner is a heat pump, which moves heat from inside to outside. Moving heat takes less energy than making it. The Cirro 12000 moves 3.52 kWh of heat for 1.35 kWh of electricity.

Sources

  1. NIST: SP 811, Appendix B.9, conversion factors (checked 14 November 2026)
  2. Meaco: Cirro 12000 BTU portable air conditioner and heater (checked 13 November 2026; could not re-open on 14 November)
  3. Viessmann UK: how many BTU to heat a room (checked 14 November 2026)
  4. Ofgem: changes to the energy price cap, 1 October to 31 December 2026 (checked 13 November 2026)

Products on this page

  • Meaco

    Cirro 12000 BTU Super Quiet Smart Portable Air Conditioner & Heater (A-Cirro-12K-CH)

    12,000 BTU · 45 dB · 1,350 W · 36p an hour

    £539.99 at Meaco (maker shop), checked 13 Nov 2026

    See it at Meaco (maker shop)

Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.