Key takeaways
- The highest label SCOP in our library is 5.2, for the Daikin Perfera 2.5 kW and the Mitsubishi Electric MSZ-LN25VG3, both A+++ for heating (see our air to air heat pump guide for what these systems do). At SCOP 5.2 a kWh of heat costs 5.1p, against 8.9p from a 90% gas boiler.
- In this best air to air heat pump list, Daikin’s Emura and Stylish are close behind at SCOP 5.15.
- Of the units in this list, only Bosch publishes heating output at -7C in the document we read: 2.2 kW for the Climate 3200i 3.5 kW.
- We have not tested any of them. The list is ordered by the maker’s label SCOP, not by our opinion.
- They heat room air: MCS says many air-to-air heat pumps do not provide hot water. When we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed.
Which is the best air to air heat pump? For heating, the fairest single measure is SCOP, the seasonal efficiency on the energy label: the higher it is, the less electricity each unit of heat costs. Below we list every home unit in our product library with a published label SCOP of 4.2 or more, highest first, then pick out the ones that suit particular needs. Our air to air heat pump guide explains what these systems do and do not do.
How we chose
- The rule that orders the list: SCOP in the energy label’s average climate, as the maker or its retailer publishes it. Ties are listed by name.
- Which units are in it: every file in our product library for a home split, multi split or ducted unit that is on UK sale (status current) and has a label SCOP of 4.2 or more. That is 17 units. Units with a label SCOP below 4.2 are not listed. We left out two Daikin Round Flow ceiling cassettes, because they are commercial units (Daikin’s Sky Air range), and portables with a heat mode (see portable air conditioners with heating).
- What we add: heating output, heating class, indoor noise, the cost per kWh of heat at the October to December 2026 price cap, and a label running cost where the maker publishes yearly heating kWh.
- What we do not do: test units, give scores, or call anything “best” overall. Headings say what each unit’s figures support.
The cost of heat is 26.32p (Ofgem’s Great Britain average electricity rate for 1 October to 31 December 2026, which carries no VAT (0%) for this period) divided by the SCOP. Gas at 7.97p (5% VAT) in a boiler at 90% efficiency, the figure a Department for Energy Security and Net Zero (DESNZ) report uses for combi condensing boilers, gives 8.9p. In Northern Ireland, use the unit rate on your own bill. A label SCOP is a test figure: DESNZ modelled real air to air systems at “around 2.5:1 to around 4:1”, and at 2.5 heat costs 10.5p per kWh, more than gas. None of this is a promised saving.
Comparison table
| Unit | Type | Heating output (kW) | SCOP (average climate) | Heating class | Pence per kWh of heat | Indoor sound pressure (dB(A), lowest to highest) |
|---|---|---|---|---|---|---|
| Daikin Perfera 2.5 kW | Wall split | 2.8 | 5.2 | A+++ | 5.1p | 19 to 41 |
| Mitsubishi Electric MSZ-LN25VG3 | Wall split | 3.2 | 5.2 | A+++ | 5.1p | 19 to 42 |
| Daikin Emura 2.0 kW | Wall split | 2.5 | 5.15 | A+++ | 5.1p | 19 to 39 |
| Daikin Emura 2.5 kW | Wall split | 2.8 | 5.15 | A+++ | 5.1p | 19 to 40 |
| Daikin Stylish 2.5 kW | Wall split | 2.8 | 5.15 | Not stated | 5.1p | 19 to 40 |
| Daikin Perfera floor 2.4 kW | Floor console | 3.4 | 4.7 | A++ | 5.6p | 20 to 38 |
| Daikin Comfora 3.5 kW | Wall split | 4 | 4.64 | A++ | 5.7p | 20 to 43 |
| Daikin 2MXM50A with two Perfera 2.5 kW | Multi split, 2 rooms | 5.6 | 4.61 | A++ | 5.7p | Not stated for the pair |
| electriQ iQool 12000 | Wall split | 3.8 | 4.6 | A++ | 5.7p | Not stated |
| electriQ iQool 9000 | Wall split | 3 | 4.6 | A++ | 5.7p | Not stated |
| Hitachi airHome 400 3.5 kW | Wall split | 4.2 | 4.6 | A++ | 5.7p | 20 to 44 |
| Toshiba Seiya 1.5 kW | Wall split | 2 | 4.6 | A++ | 5.7p | 19 to 37 |
| Toshiba Seiya 2.5 kW | Wall split | 3.2 | 4.6 | A++ | 5.7p | 20 to 39 |
| Fujitsu ASYG12KMCC 3.4 kW | Wall split | 4 | 4.4 | A+ | 6.0p | 20 to 40 |
| Bosch Climate 3200i 3.5 kW | Wall split | 2.2 at -7C (nominal not stated) | 4.2 | A+ | 6.3p | Not stated |
| Daikin Sensira 2.0 kW | Wall split | 2.4 | 4.2 | A+ | 6.3p | 20 to 39 |
| Daikin Sensira 2.5 kW | Wall split | 2.8 | 4.2 | A+ | 6.3p | 20 to 40 |
Sound figures are the makers’ indoor sound pressure by fan speed, in cooling where the maker says so (Hitachi’s page does not label its figures). Noise from retailer listings that do not say indoor or outdoor is left as not stated.
Highest heating efficiency: Daikin Perfera 2.5 kW
Who it suits: one room heated as efficiently as any unit in our list, where a wall unit high up is acceptable. Key figures (Daikin UK table): 2.8 kW heating, SCOP 5.20, A+++ for heating, 647 kWh of electricity a year for heating at a 2.40 kW design load; indoor sound pressure 19 dB(A) silent to 41 dB(A) high in cooling. Running cost: 647 kWh x 26.32p = £170.29 a year for heating. The label counts 1,400 hours, so 2.4 kW x 1,400 = 3,360 kWh of heat; a 90% gas boiler would burn 3,733.3 kWh of gas for it, £297.55 at 7.97p. Cooling: 92 kWh, £24.21 a year. What to watch for: Daikin UK publishes no prices, and we found no installed price for this exact pairing. See the Daikin Perfera review and Daikin heat pumps.
Equal highest SCOP: Mitsubishi Electric MSZ-LN25VG3
Who it suits: the same job as the Perfera, from Mitsubishi Electric, with more heating output. Key figures (Mitsubishi Electric product information sheet, February 2026): 3.2 kW heating, SCOP 5.2, A+++ for heating; indoor sound pressure 19 to 42 dB(A) in cooling. Mitsubishi Electric UK calls the MSZ-LN an “Inverter Heat Pump”. Running cost: 5.1p per kWh of heat. The sheet gives no yearly heating kWh, so we do not give a label year. What to watch for: the VG3 is the current generation; our library lists the older VG2, LN50VG and LN60VG codes as discontinued. See Mitsubishi air to air heat pumps.
Near the top, with a design focus: Daikin Emura and Stylish
Who they suit: rooms where the look of the indoor unit matters. Key figures: Emura 2.5 kW, 2.8 kW heating, SCOP 5.15, A+++; Emura 2.0 kW, 2.5 kW heating, SCOP 5.15, A+++ (Daikin UK table); Stylish 2.5 kW, 2.8 kW heating, SCOP 5.15 (Daikin’s Stylish brochure; its heating class did not come through in the text we could read). All three go down to 19 dB(A) in silent mode. Running cost: 5.1p per kWh of heat. What to watch for: our product files record no UK price for them. See the Emura and Stylish reviews.
Warm air from low down: Daikin Perfera floor 2.4 kW
Who it suits: heating-led rooms, because the console sits low and blows warm air near the floor. Key figures (Daikin UK table): 3.4 kW heating, SCOP 4.70, A++; 20 to 38 dB(A) in cooling. Running cost: 5.6p per kWh of heat. What to watch for: it still needs an outdoor unit, pipework and an F-gas certified installer.
Two rooms on one outdoor unit: Daikin 2MXM50A multi split
Who it suits: two rooms where one outdoor unit is wanted. Key figures (Daikin UK table): with two Perfera 2.5 kW indoor units, 5.6 kW heating, SCOP 4.61, A++. Multi split figures are for that combination; other indoor units rate differently. Running cost: 5.7p per kWh of heat. See multi split air conditioning.
Small rooms: Toshiba Seiya 1.5 kW and 2.5 kW
Who they suit: a small bedroom or study (the 1.5 kW) or a standard room (the 2.5 kW). Key figures (Toshiba’s 2026 retail price list (updated 17 November 2026), as read on 28 November 2026): 1.5 kW model, 2.0 kW heating, SCOP 4.6, A++, 19 to 37 dB(A); 2.5 kW model, 3.2 kW heating, SCOP 4.6, A++, 20 to 39 dB(A). Running cost: 5.7p per kWh of heat. What to watch for: Toshiba’s list (updated 17 November 2026), as read on 28 November 2026, gives a system list price but does not say whether VAT is included, and it is not a retailer’s selling price, so we do not quote it. See the Toshiba Seiya review.
Published cold-weather figures: Bosch Climate 3200i 3.5 kW
Who it suits: buyers who want to see output and efficiency in cold weather on paper. Key figures (Worcester Bosch data sheet): SCOP 4.2 in the average climate and 3.4 in the colder one; A+; 2.5 kW design load and 833 kWh a year; declared heating capacity 2.2 kW and COP 2.8 at -7C outside; the label’s operating limit temperature for heating (average climate) is -10C. Worcester Bosch describes “Heating, cooling, dehumidifying, and purifying from a single unit”. Running cost: 833 kWh x 26.32p = £219.25 a year; the same 3,500 kWh of heat from gas at 90% costs £309.94. Cooling: 182 kWh, £47.90. Where to buy: iHeat lists a Bosch Climate 3200i 2.6 kW at £2,715 installed including VAT (page checked 15 November 2026). BOXT’s “installed from £2,299” is based on a different model, the Bosch Climate 3000i 2.6 kW. See Bosch air to air heat pumps.
Installed prices published: Daikin Sensira
Who it suits: a single-room install where you want a published installed price to compare against. Key figures (Daikin UK table): 2.5 kW model, 2.8 kW heating, SCOP 4.20, A+, 20 to 40 dB(A); 2.0 kW model, 2.4 kW heating, SCOP 4.2, A+. Running cost: 6.3p per kWh of heat. Where to buy: Costco lists an installed Sensira 2.5 kW at £1,849.99 (checked 15 November 2026; Costco’s published prices are for members only, and the listing says a 16 amp supply must be in place at the outdoor unit first). iHeat lists the Sensira 3.5 kW at £2,495 installed including VAT. See the Daikin Sensira review.
Retailer-listed units: electriQ
Who they suit: buyers who already have an F-gas certified installer lined up. Key figures (Appliances Direct listings): electriQ iQool 9000, 3.0 kW heating, SCOP 4.6, A++; iQool 12000, 3.8 kW, SCOP 4.6, A++. Where to buy: listed at £429.98 (iQool 9000) and £479.98 (iQool 12000) at Appliances Direct , both checked 25 November 2026. Check what each price includes before ordering. The listings say “The unit must be installed by a F-Gas qualified AC engineer”. See electriQ.
The rest of the table (Daikin Comfora 3.5 kW, Hitachi airHome 400 and Fujitsu ASYG12KMCC) are listed for completeness; see Daikin Comfora, Hitachi and Fujitsu. The Fujitsu’s label gives 795 kWh a year for heating: £209.24.
Worth knowing about, UK sale not confirmed
The Panasonic Etherea 2.5 kW and the LG DualCool EZ12 appear in our library, but we could not confirm that either is on UK sale from a maker’s UK document, so neither is a pick. See Panasonic and LG.
Hot water: plan it separately
MCS says “many air-to-air heat pumps do not provide hot water, so you may need an additional system”. If one of these replaces a gas boiler, plan the hot water first: Ofgem’s grant rules allow “immersion heaters” and “hot water heat pumps” alongside a heat pump.
Prices: installed, not shelf
A split must be fitted by an F-gas certified company, so the price that matters is the installed one. Published installed prices for one room run from £1,500 to £4,000 (OVO, Fuse Energy, Nesta); see air to air heat pump cost. Installing a fixed heat pump in a home is zero-rated for VAT until 31 March 2027, then 5%.
The grant: in England and Wales the Boiler Upgrade Scheme has offered £2,500 towards an air-to-air heat pump that replaces the home’s heating and can heat the whole home, since 28 April 2026, through an MCS certified installer (Ofgem installer guidance V5.2, paragraphs 1.06, 3.75, 3.80 and 3.89). When we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed. What must be replaced differs by source: Ofgem’s guidance says a fossil fuel system or “an electric heating system that does not include a heat pump” (3.37); GOV.UK’s guide says “fossil fuel heating systems - such as oil, gas, electric or LPG”; MCS says “the replacement of a fossil fuel heating appliance”. See the grant guide.
For cooling-led picks see best wall mounted air conditioners and energy efficient air conditioners; for owners’ experience see air to air heat pump reviews and efficiency.
Frequently asked questions
Which air to air heat pump is most efficient?
In our library, the Daikin Perfera 2.5 kW and Mitsubishi Electric MSZ-LN25VG3, both SCOP 5.2 and A+++ for heating on their makers’ figures.
Which works best in cold weather?
We cannot compare them fairly: only Bosch’s data sheet, of those we read, gives output at -7C (2.2 kW for the Climate 3200i 3.5 kW, COP 2.8). Ask any installer for the unit’s output at your area’s design temperature.
Which is quietest?
Several go down to 19 dB(A) indoors in silent mode on their makers’ figures: Daikin Perfera, Emura and Stylish, Mitsubishi Electric MSZ-LN25VG3 and Toshiba Seiya 1.5 kW. Sound pressure figures depend on how the maker measures them.
Can I buy one without installation?
You can buy some units on their own, but a split holding F-gas must be fitted by an F-gas certified company, and a unit supplied without installation pays 20% VAT.
Which brands qualify for the grant?
The £2,500 grant for air-to-air heat pumps has been in law in England and Wales since 28 April 2026, but when we checked on 25 November 2026, MCS said no installer was yet certified for air-to-air heat pumps, so the grant could not then be claimed for any brand.
Sources
- Daikin UK: FTXM-A and RXM-A9 specifications table (Perfera) (checked 15 November 2026)
- Daikin UK: FTXM-A indoor unit table (checked 15 November 2026)
- Mitsubishi Electric UK: MSZ-LN R32 product information sheet (PDF) (checked 15 November 2026)
- Mitsubishi Electric UK: MSZ-LN R32 Inverter Heat Pump (checked 15 November 2026)
- Daikin UK: FTXJ-AW and RXJ-A9 specifications table (Emura) (checked 15 November 2026)
- Daikin UK: FTXJ-AW indoor unit table (checked 15 November 2026)
- Daikin UK: Stylish brochure (PDF) (checked 15 November 2026)
- Daikin UK: FVXM-B and RXM-A9 specifications table (Perfera floor) (checked 15 November 2026)
- Daikin UK: FVXM-B indoor unit table (checked 15 November 2026)
- Daikin UK: FTXP-N and RXP-N9 specifications table (Comfora) (checked 15 November 2026)
- Daikin UK: FTXP-N indoor unit table (checked 15 November 2026)
- Daikin UK: FTXM-A and 2MXM-A8 multi split table (checked 15 November 2026)
- Hitachi: airHome 400 (checked 15 November 2026)
- Toshiba’s 2026 retail price list (GBP edition, updated 17 November 2026) (checked 28 November 2026)
- GENERAL (Fujitsu): ASYG KMCC specifications (PDF) (checked 15 November 2026)
- Worcester Bosch: Climate 3200i 3.5 kW energy data sheet (PDF) (checked 15 November 2026)
- Worcester Bosch: Climate 3200i single split (checked 15 November 2026)
- Daikin UK: FTXF-F and RXF-F specifications table (Sensira) (checked 15 November 2026)
- Daikin UK: FTXF-F indoor unit table (checked 15 November 2026)
- Appliances Direct: electriQ iQool9Plus (checked 25 November 2026)
- Appliances Direct: electriQ iQool12Plus (checked 25 November 2026)
- iHeat: Air conditioning packages (checked 15 November 2026)
- BOXT: Air conditioning (checked 15 November 2026)
- Costco: Installed Daikin Sensira 2.5 kW single split, domestic (checked 15 November 2026)
- Ofgem: Energy price cap unit rates and standing charges (checked 15 November 2026)
- DESNZ: Understanding the suitability of reversible air-to-air heat pumps for domestic use in the UK (9 July 2026, PDF) (checked 15 November 2026)
- MCS: Air-to-air heat pumps (checked 25 November 2026)
- HMRC: VAT Notice 708/6 (checked 15 November 2026)
- Ofgem: Boiler Upgrade Scheme, Guidance for Installers V5.2 (PDF) (checked 25 November 2026)
- OVO: Air conditioning installation cost (16 June 2026) (checked 15 November 2026)
Other products mentioned
Daikin
Emura FTXJ20A2V1BW (indoor) with RXJ20A5V1B9 (outdoor), 2.0 kW
2 kW cooling · 39 dB · SEER 8.75
No current UK price found
Daikin
Emura FTXJ25A2V1BW (indoor) with RXJ25A5V1B9 (outdoor), 2.5 kW
2.5 kW cooling · 40 dB · SEER 8.74
No current UK price found
Daikin
Stylish FTXA25-C/D (indoor) with RXA25A8 (outdoor), 2.5 kW
2.5 kW cooling · 40 dB · SEER 8.74
No current UK price found
Daikin
Comfora FTXP35N5V1B (indoor) with RXP35N5V1B9 (outdoor), 3.5 kW
3.5 kW cooling · 43 dB · SEER 7.2
No current UK price found
Hitachi
airHome 400 RAK-DJ35PHAE (indoor) with RAC-DJ35PHAE (outdoor), 3.5 kW
3.5 kW cooling · 44 dB · SEER 7.5
No current UK price found
Toshiba
Seiya RAS-B10S4KVG-E (indoor) with RAS-10E2AVG-E (outdoor), 2.5 kW
2.5 kW cooling · 39 dB · SEER 7
No current UK price found
electriQ
iQool 12000 BTU Smart A+++ Wall Mounted Split Air Conditioner with Heat Pump, 5m pipe kit (iQool12Plus)
12,000 BTU · 1,000 W · 26p an hour · 30 m²
£479.98 at Appliances Direct, checked 14 Nov 2026
See it at Appliances DirectelectriQ
iQool 9000 BTU Smart A+++ Wall Mounted Split Air Conditioner with Heat Pump, 5m pipe kit (iQool9Plus)
9,000 BTU · 660 W · 17p an hour · 26 m²
£429.98 at Appliances Direct, checked 14 Nov 2026
See it at Appliances DirectFujitsu
ASYG12KMCC (indoor) with AOYG12KMCC (outdoor), 3.4 kW
3.4 kW cooling · 40 dB · SEER 7.3
No current UK price found
Daikin
Sensira FTXF20F5V1B (indoor) with RXF20F5V1B (outdoor), 2.0 kW
2 kW cooling · 39 dB · SEER 6.5
No current UK price found
Daikin
Sensira FTXF25F5V1B (indoor) with RXF25F5V1B (outdoor), 2.5 kW
2.5 kW cooling · 40 dB · SEER 6.5
No current UK price found
Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.